The electrified drain. A new device for sterilizing the field of drainage.

A Shafik1.   

Abstract

A randomized control study was performed on 24 patients to evaluate the effect of a new drainage system. Two types of drains were used: electrified and the conventional corrugated rubber drains. All of the 24 patients had an incisional hernia repair operation. In 12 patients, the wound was drained with an electrified drain (ED) and in the other 12 by the conventional drain (CD). The ED consisted of a corrugated rubber drain to which 2 silver-silver chloride electrodes were fixed. The wounds were drained for the first 3 post-operative days during which antibiotics were given. A peroperative and daily swab from the wound was taken during the time of drainage and for 4 days thereafter, and cultured. For evaluation, a pathogen count of less than 10(5) colony-forming units per ml of discharge from wound cultures was considered as successful drainage, while counts above this level were defined as failures. Drainage failure occurred in 4/12 patients (33%) of the CD group. Pathogens encountered were Streptococcus pyogenes, Staphylococcus aureus and albus and P. aeruginosa. Manifestations of wound inflammation occurred in 2 of the 4 patients. The appropriate antibiotic was given to the 4 patients after culture and sensitivity tests were performed. Drainage failure did not occur in any of the ED group. Post-operative laboratory assessment of blood count, liver and kidney functions and serum electrolytes recorded insignificant changes against preoperative values in both groups. The results demonstrate the superiority of the ED over the CD. The electric field produced by the ED seems to be lethal to organisms. The ED is simple, safe and cost-effective.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8175269

Source DB:  PubMed          Journal:  Int Surg        ISSN: 0020-8868


  3 in total

1.  Electrical microcurrent to prevent conditioning film and bacterial adhesion to urological stents.

Authors:  Michael Gabi; Lukas Hefermehl; Danijela Lukic; Raphael Zahn; Janos Vörös; Daniel Eberli
Journal:  Urol Res       Date:  2010-08-05

2.  Drain Placement Does Not Increase Infectious Complications After Retromuscular Ventral Hernia Repair with Synthetic Mesh: an AHSQC Analysis.

Authors:  David M Krpata; Ajita S Prabhu; Alfredo M Carbonell; Ivy N Haskins; Sharon Phillips; Benjamin K Poulose; Michael J Rosen
Journal:  J Gastrointest Surg       Date:  2017-10-05       Impact factor: 3.452

3.  The electrified catheter. Role in sterilizing urine and decreasing bacteriuria.

Authors:  A Shafik
Journal:  World J Urol       Date:  1993       Impact factor: 4.226

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.