Literature DB >> 8168406

Measurement of microtomy-induced section distortion and its correction for 3-dimensional histological reconstructions.

A S Jones1, B K Milthorpe, C R Howlett.   

Abstract

The presence of microtomy induced distortion in paraffin sections is a significant hindrance to the accurate alignment of sections for three-dimensional reconstructive techniques. Measurements of section distortion in various rat tissues demonstrated distortions to be present in all sections, with over 85% of such distortions being manifest as expansions when compared to the original distances between a series of eight drilled fiducial marks. Mean percentage dimensional changes in the direction of the cutting stroke and at right angles to this direction were -0.5 +/- 1.5% and 3.7 +/- 1.2% for liver, 7.6 +/- 2.4% and 9.1 +/- 1.2% for kidney, 6.6 +/- 2.3% and 10.5 +/- 1.4% for lung, and 20.3 +/- 6.6% and 8.9 +/- 5.9% for skeletal muscle. Individual sections invariably displayed measurable distortions, with only skeletal muscle showing any consistent pattern, in the form of "barrel" distortion at right angles to the cutting stroke. In addition a method of distortion correction and simultaneous image alignment is presented as a means of section alignment with full distortion correction capability. This method uses a quadratic polynomial transform in a non-linear "unwarping" algorithm, to correct for the rotational and translational misalignment as well as for microtomy and camera aspect ratio distortions. Application of this method to a sequence of 46 serial sections demonstrated an alignment accuracy to within 2.6 +/- 0.8 pixels.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8168406     DOI: 10.1002/cyto.990150203

Source DB:  PubMed          Journal:  Cytometry        ISSN: 0196-4763


  4 in total

1.  Nondestructive volumetric imaging of tissue microstructure with benchtop x-ray phase-contrast tomography and critical point drying.

Authors:  Adam M Zysk; Alfred B Garson; Qiaofeng Xu; Eric M Brey; Wei Zhou; Jovan G Brankov; Miles N Wernick; Jerome R Kuszak; Mark A Anastasio
Journal:  Biomed Opt Express       Date:  2012-07-24       Impact factor: 3.732

2.  Morphometrics of the Spinal Cord and Surrounding Structures in Alligator mississippiensis.

Authors:  Skye Greer; Michael J Cramberg; Bruce A Young
Journal:  Biology (Basel)       Date:  2022-03-27

3.  Validation of airway wall measurements by optical coherence tomography in porcine airways.

Authors:  Anthony M D Lee; Miranda Kirby; Keishi Ohtani; Tara Candido; Rebecca Shalansky; Calum MacAulay; John English; Richard Finley; Stephen Lam; Harvey O Coxson; Pierre Lane
Journal:  PLoS One       Date:  2014-06-20       Impact factor: 3.240

4.  X-ray based virtual histology allows guided sectioning of heavy ion stained murine lungs for histological analysis.

Authors:  Jonas Albers; M Andrea Markus; Frauke Alves; Christian Dullin
Journal:  Sci Rep       Date:  2018-05-16       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.