Literature DB >> 8168399

Simultaneous measurement of two cellular antigens and DNA using fluorescein-isothiocyanate, R-phycoerythrin, and propidium iodide on a standard FACScan.

W E Corver1, C J Cornelisse, G J Fleuren.   

Abstract

Multiparameter flow cytometry is a powerful tool for analyzing the phenotypic, cell kinetic, and ploidy heterogeneity of tumor cell populations. Because of the substantial spectral overlap of propidium iodide (PI) and R-phycoerythrin (PE) fluorescence emission, this combined use of these fluorochromes has been thought not to be feasible on a standard flow cytometer for these kind of studies. Instead of PI, 7-amino-actinomycin D (7-AAD) is used as DNA stain. In this paper however, we show that PI can be used as a DNA stain in combination with fluorescein isothiocyanate (FITC) and R-phycoerythrin (PE) on a standard FACScan. Three established ovarian cancer cell lines (IGROV1, NIH: OVCAR-3, and COV362.c14) were used for these experiments. Cells were fixed with 1.0% paraformaldehyde and permeabilized with various concentrations of lysolecithin for the simultaneous detection of surface antigens by monoclonal antibodies MOv18, BMA180 or OV632, intermediate filament antigens (keratin 18 or vimentin), and DNA. A final concentration of 80 micrograms/ml lysolecithin was found to give optimal results. The emission spectrum overlap from PI into the orange fluorescence channel (FL2) used for PE fluorescence detection could be sufficiently compensated up to a photomultiplier tube potential of about 440 Volts (V) required at the FL2 channel. Using the same instrument settings, 5.10 x 10(4) PE equivalents were detectable. Under these conditions, CVs obtained for the DNA histograms ranged from 3.0-4.1. Application of the method on a mixture of activated peripheral blood lymphocytes and ovarian tumor cells resulted in a clear separation of the two populations both by surface and cytoplasmic antigen expression and DNA content.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8168399     DOI: 10.1002/cyto.990150205

Source DB:  PubMed          Journal:  Cytometry        ISSN: 0196-4763


  6 in total

1.  Use of the glycophorin A somatic mutation assay for rapid, unambiguous identification of Fanconi anemia homozygotes regardless of GPA genotype.

Authors:  Viktoria N Evdokimova; Reagan K McLoughlin; Sharon L Wenger; Stephen G Grant
Journal:  Am J Med Genet A       Date:  2005-05-15       Impact factor: 2.802

2.  Data-driven compensation for flow cytometry of solid tissues.

Authors:  Nickolaas Maria van Rodijnen; Math Pieters; Sjack Hoop; Marius Nap
Journal:  Adv Bioinformatics       Date:  2011-09-06

3.  Multiple genetic alterations cause frequent and heterogeneous human histocompatibility leukocyte antigen class I loss in cervical cancer.

Authors:  L A Koopman; W E Corver; A R van der Slik; M J Giphart; G J Fleuren
Journal:  J Exp Med       Date:  2000-03-20       Impact factor: 14.307

4.  Molecular genetic analysis of flow-sorted ovarian tumour cells: improved detection of loss of heterozygosity.

Authors:  E C Abeln; W E Corver; N J Kuipers-Dijkshoorn; G J Fleuren; C J Cornelisse
Journal:  Br J Cancer       Date:  1994-08       Impact factor: 7.640

5.  Outgrowth of BT-474 human breast cancer cells in immune-deficient mice: a new in vivo model for hormone-dependent breast cancer.

Authors:  H J van Slooten; B A Bonsing; A J Hiller; G T Colbern; J H van Dierendonck; C J Cornelisse; H S Smith
Journal:  Br J Cancer       Date:  1995-07       Impact factor: 7.640

6.  E-cadherin transcriptional downregulation by promoter methylation but not mutation is related to epithelial-to-mesenchymal transition in breast cancer cell lines.

Authors:  M Lombaerts; T van Wezel; K Philippo; J W F Dierssen; R M E Zimmerman; J Oosting; R van Eijk; P H Eilers; B van de Water; C J Cornelisse; A-M Cleton-Jansen
Journal:  Br J Cancer       Date:  2006-03-13       Impact factor: 7.640

  6 in total