Literature DB >> 8168344

Evaluation of multi-frequency bio-impedance analysis for the assessment of extracellular and total body water in surgical patients.

W J Hannan1, S J Cowen, K C Fearon, C E Plester, J S Falconer, R A Richardson.   

Abstract

1. Multi-frequency bio-impedance analysis has been used to estimate extracellular and total body water in a heterogeneous group of 43 surgical patients (23 males, 20 females). 2. Radioisotope-dilution methods were used for the measurement of extracellular and total body water. 3. Resistance and reactance were measured between wrist and ankle at frequencies from 5 kHz to 1 MHz. 4. Extracellular and total body water were estimated by multiple stepwise regression using the radioisotope values as the dependent variables. The parameters included in the regression were: resistance and reactance at each frequency, body habitus parameters, plasma albumin and plasma sodium. 5. The standard errors of the estimates between the measured and estimated values were 1.73 litres (coefficient of variation 9.6%) and 2.17 litres (coefficient of variation 6.0%) for extracellular and total body water, respectively. 6. These errors represent a useful improvement relative to those obtained from anthropometric estimates. However, the improvements relative to the use of a single frequency (50 kHz) are not clinically significant.

Entities:  

Mesh:

Year:  1994        PMID: 8168344     DOI: 10.1042/cs0860479

Source DB:  PubMed          Journal:  Clin Sci (Lond)        ISSN: 0143-5221            Impact factor:   6.124


  13 in total

Review 1.  Body composition analysis in older adults with dementia. Anthropometry and bioelectrical impedance analysis: a critical review.

Authors:  M A Camina Martín; B de Mateo Silleras; M P Redondo del Río
Journal:  Eur J Clin Nutr       Date:  2014-08-13       Impact factor: 4.016

Review 2.  Bioelectrical impedance analysis to estimate body composition in surgical and oncological patients: a systematic review.

Authors:  E B Haverkort; P L M Reijven; J M Binnekade; M A E de van der Schueren; C P Earthman; D J Gouma; R J de Haan
Journal:  Eur J Clin Nutr       Date:  2014-10-01       Impact factor: 4.016

3.  Electrical Impedance Myography for Evaluating Paretic Muscle Changes After Stroke.

Authors:  Xiaoyan Li; Le Li; Henry Shin; Sheng Li; Ping Zhou
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2017-05-26       Impact factor: 3.802

4.  Extracellular volume measurements using bioimpedance spectroscopy-Hanai method and wrist-ankle resistance at 50 kHz.

Authors:  Michel Y Jaffrin; Hélène Morel
Journal:  Med Biol Eng Comput       Date:  2008-09-17       Impact factor: 2.602

5.  Monitoring of body water composition by the simultaneous use of bioelectrical impedance analysis and Crit-Line(®) during hemodialysis.

Authors:  Naoki Sugano; Keitaro Yokoyama; Naohiko Kato; Yoichiro Hara; Satoshi Endo; Jun Mitome; Taisei Kin; Goro Tokudome; Satoru Kuriyama; Tatsuo Hosoya; Takashi Yokoo
Journal:  Clin Exp Nephrol       Date:  2014-02-12       Impact factor: 2.801

6.  A pilot study of megestrol acetate and ibuprofen in the treatment of cachexia in gastrointestinal cancer patients.

Authors:  D C McMillan; P O'Gorman; K C Fearon; C S McArdle
Journal:  Br J Cancer       Date:  1997       Impact factor: 7.640

7.  Effective and timely evaluation of pulmonary congestion: qualitative comparison between lung ultrasound and thoracic bioelectrical impedance in maintenance hemodialysis patients.

Authors:  Carlo Donadio; Laura Bozzoli; Elisa Colombini; Giovanna Pisanu; Guido Ricchiuti; Eugenio Picano; Luna Gargani
Journal:  Medicine (Baltimore)       Date:  2015-02       Impact factor: 1.889

8.  Hand-to-Hand Model for Bioelectrical Impedance Analysis to Estimate Fat Free Mass in a Healthy Population.

Authors:  Hsueh-Kuan Lu; Li-Ming Chiang; Yu-Yawn Chen; Chih-Lin Chuang; Kuen-Tsann Chen; Gregory B Dwyer; Ying-Lin Hsu; Chun-Hao Chen; Kuen-Chang Hsieh
Journal:  Nutrients       Date:  2016-10-21       Impact factor: 5.717

9.  Ibuprofen reduces energy expenditure and acute-phase protein production compared with placebo in pancreatic cancer patients.

Authors:  S J Wigmore; J S Falconer; C E Plester; J A Ross; J P Maingay; D C Carter; K C Fearon
Journal:  Br J Cancer       Date:  1995-07       Impact factor: 7.640

Review 10.  Clinical usefulness of bioimpedance analysis for assessing volume status in patients receiving maintenance dialysis.

Authors:  Jung Hwan Park; Young-Il Jo; Jong-Ho Lee
Journal:  Korean J Intern Med       Date:  2018-06-28       Impact factor: 2.884

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.