The head-scatter factor for small field sizes.

T C Zhu1, B E Bjärngard.   

Abstract

The head-scatter factors H were examined for four different linear accelerators and were found to be similar at field sizes larger than 3 x 3 cm2. Sharply reduced values for small collimator openings were observed for all the accelerators. It is concluded that the head-scatter (or collimator-scatter) factor has two major components. Scatter of photons in various structures in the beam path, especially the flattening filter, causes a slow (about 10%) increase with increased collimator opening. Insertion of a built-in wedge may double this number. When the collimators are closed, they ultimately block photons from the periphery of the source. This may cause a considerable reduction of the primary photon fluence and typically affects fields smaller than 3 x 3 cm2. The effect can be used to estimate the source size, with results that correlate with the design of the bending magnet.

Mesh:

Year:  1994        PMID: 8164590     DOI: 10.1118/1.597256

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  7 in total

1.  A convolution/superposition method using primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance: a theoretical study on 10-MV X-ray dose calculations in thorax-like phantoms.

Authors:  Akira Iwasaki; Shigenobu Kimura; Kohji Sutoh; Kazuo Kamimura; Makoto Sasamori; Fumio Komai; Morio Seino; Singo Terashima; Mamoru Kubota; Junichi Hirota; Yoichiro Hosokawa
Journal:  Radiol Phys Technol       Date:  2011-06-15

2.  Estimation of focal and extra-focal radiation profiles based on Gaussian modeling in medical linear accelerators.

Authors:  Shigeo Anai; Hidetaka Arimura; Katsumasa Nakamura; Fujio Araki; Takaomi Matsuki; Hideki Yoshikawa; Satoshi Yoshidome; Yoshiyuki Shioyama; Hiroshi Honda; Nobuo Ikeda
Journal:  Radiol Phys Technol       Date:  2011-03-24

3.  On the quantification of the dosimetric accuracy of collapsed cone convolution superposition (CCCS) algorithm for small lung volumes using IMRT.

Authors:  Oscar I Calvo; Alonso N Gutiérrez; Sotirios Stathakis; Carlos Esquivel; Nikos Papanikolaou
Journal:  J Appl Clin Med Phys       Date:  2012-05-10       Impact factor: 2.102

4.  Monte Carlo Dose Calculation - A QA Method for SRT and SBRT Plans in Treating Multiple and Small Metastatic Lesions.

Authors:  Teh Lin; Lu Wang; C-M Charlie Ma
Journal:  J Med Phys       Date:  2022-03-31

5.  Percentage depth dose calculation accuracy of model based algorithms in high energy photon small fields through heterogeneous media and comparison with plastic scintillator dosimetry.

Authors:  Ananda Giri Babu Alagar; Ganesh Kadirampatti Mani; Kaviarasu Karunakaran
Journal:  J Appl Clin Med Phys       Date:  2016-01-08       Impact factor: 2.102

6.  An Experimental Slope Method for a More Accurate Measurement of Relative Radiation Doses using Radiographic and Radiochromic Films and Its Application to Megavoltage Small-Field Dosimetry.

Authors:  Raghavendra Holla; D Khanna; Bhaskaran K Pillai; K V Jafar Ali; P S Renil Mon; C O Clinto; Tharmarnadar Ganesh
Journal:  J Med Phys       Date:  2019 Jul-Sep

7.  Design of mini phantom and measurement of cobalt-60 beam data parameters.

Authors:  S Senthilkumar; V Ramakrishnan
Journal:  J Med Phys       Date:  2008-07
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.