Effect of hip position on gravity effect torque.

W J Ford1, S D Bailey, K Babich, T W Worrell.   

Abstract

Hip position has been hypothesized to influence gravity effect torque (GET) at the knee during isokinetic testing; however, no data exist to support or refute this hypothesis. Therefore, the purposes of this study were 1) to determine if a significant difference exists between GET in seated and supine positions, 2) to determine the effect of the supine and seated GET on isokinetic peak torque values, and 3) to determine the relationship between hamstring flexibility and GET. Gravity effect torque was recorded in supine and seated positions. Peak torque values in flexion and extension were obtained on a isokinetic dynamometer at 1.047 and 5.235 rads.s-1 (60 and 300 degrees.s-1, respectively). Hamstring flexibility was assessed by the active knee extension test (AKET). The mean seated GET value was 5.64 Nm higher than the mean supine GET value (F(1,82) = 97.85, P = 0.0001). Significant correlations existed between hamstring flexibility and GET values measured in the seated and supine positions (r = 0.45, P = 0.0001, and r = 0.30, P = 0.0058, respectively). Significant differences in peak torque values occurred for three of the four isokinetic conditions when using different GET values (P-value 0.0002-0.0049). Although mean differences in peak torque values were only 2.43-4.23 Nm, these differences may translate to significant errors in the isokinetic measurement of the injured population undergoing rehabilitation. Furthermore, every attempt should be made to improve the validity of isokinetic testing. Therefore, we recommend the supine position for GET determination.

Mesh:

Year:  1994        PMID: 8164541     DOI: 10.1249/00005768-199402000-00014

Source DB:  PubMed          Journal:  Med Sci Sports Exerc        ISSN: 0195-9131            Impact factor:   5.411


  3 in total

Review 1.  Isokinetic eccentric exercise.

Authors:  E Kellis; V Baltzopoulos
Journal:  Sports Med       Date:  1995-03       Impact factor: 11.136

2.  A new method for gravity correction of dynamometer data and determining passive elastic moments at the joint.

Authors:  Dennis E Anderson; Maury A Nussbaum; Michael L Madigan
Journal:  J Biomech       Date:  2010-01-04       Impact factor: 2.712

3.  The Torque Referenced to a Perceived Exertion Level Is Affected by the Type of Movement in Men With Spinal Cord Injury.

Authors:  Frederico Ribeiro Neto; Rodrigo Rodrigues Gomes Costa; Bruna Pereira Avelar; Silvio Assis de Oliveira Junior; Aline Martins de Toledo; Rodrigo Luiz Carregaro
Journal:  Top Spinal Cord Inj Rehabil       Date:  2021-01-20
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.