Literature DB >> 8160962

Elimination of the acetaminophen interference in an implantable glucose sensor.

Y Zhang1, Y Hu, G S Wilson, D Moatti-Sirat, V Poitout, G Reach.   

Abstract

Acetaminophen has been one of the most serious electrochemical interferences to oxidase-based amperometric biosensors that measure H2O2. A study was carried out to investigate various polymer materials for their selectivity as the sensor inner membrane. A composite membrane of cellulose acetate and Nafion was found to eliminate acetaminophen and other electrochemical interferences effectively while at the same time maintaining reasonable diffusivity for hydrogen peroxide. The excellent in vivo performance of the sensor was attributed not only to significantly reduced steady-state sensitivity to acetaminophen but also to very slow acetaminophen response. These features, combined with rapid acetaminophen clearance pharmacokinetics, led to the decreased response as demonstrated in the rat.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8160962     DOI: 10.1021/ac00079a038

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  13 in total

1.  How to design a biosensor.

Authors:  W Kenneth Ward
Journal:  J Diabetes Sci Technol       Date:  2007-03

2.  Modulation of fibroblast inflammatory response by surface modification of a perfluorinated ionomer.

Authors:  Thelma I Valdes; Winston Ciridon; Buddy D Ratner; James D Bryers
Journal:  Biointerphases       Date:  2011-06       Impact factor: 2.456

3.  Microdialysis sampling extraction efficiency of 2-deoxyglucose: role of macrophages in vitro and in vivo.

Authors:  Xiaodun Mou; Julie A Stenken
Journal:  Anal Chem       Date:  2006-11-15       Impact factor: 6.986

4.  Fabrication of a Flexible Amperometric Glucose Sensor Using Additive Processes.

Authors:  Xiaosong Du; Christopher J Durgan; David J Matthews; Joshua R Motley; Xuebin Tan; Kovit Pholsena; Líney Árnadóttir; Jessica R Castle; Peter G Jacobs; Robert S Cargill; W Kenneth Ward; John F Conley; Gregory S Herman
Journal:  ECS J Solid State Sci Technol       Date:  2015-02-18       Impact factor: 2.070

5.  Assembling Amperometric Biosensors for Clinical Diagnostics.

Authors:  María Soledad Belluzo; María Elida Ribone; Claudia Marina Lagier
Journal:  Sensors (Basel)       Date:  2008-02-27       Impact factor: 3.576

Review 6.  Application of Semipermeable Membranes in Glucose Biosensing.

Authors:  Tanmay Kulkarni; Gymama Slaughter
Journal:  Membranes (Basel)       Date:  2016-12-14

7.  Effect of acetaminophen on CGM glucose in an outpatient setting.

Authors:  David M Maahs; Daniel DeSalvo; Laura Pyle; Trang Ly; Laurel Messer; Paula Clinton; Emily Westfall; R Paul Wadwa; Bruce Buckingham
Journal:  Diabetes Care       Date:  2015-08-12       Impact factor: 19.112

8.  Bendable Electro-chemical Lactate Sensor Printed with Silver Nano-particles.

Authors:  Md Abu Abrar; Yue Dong; Paul Kyuheon Lee; Woo Soo Kim
Journal:  Sci Rep       Date:  2016-07-28       Impact factor: 4.379

9.  Wearable/disposable sweat-based glucose monitoring device with multistage transdermal drug delivery module.

Authors:  Hyunjae Lee; Changyeong Song; Yong Seok Hong; Minsung Kim; Hye Rim Cho; Taegyu Kang; Kwangsoo Shin; Seung Hong Choi; Taeghwan Hyeon; Dae-Hyeong Kim
Journal:  Sci Adv       Date:  2017-03-08       Impact factor: 14.957

10.  Resistance to Acetaminophen Interference in a Novel Continuous Glucose Monitoring System.

Authors:  Peter Calhoun; Terri Kang Johnson; Jonathan Hughes; David Price; Andrew K Balo
Journal:  J Diabetes Sci Technol       Date:  2018-01-16
View more