Literature DB >> 8159036

Lower intensity anticoagulation therapy results in lower complication rates with the St. Jude Medical prosthesis.

D Horstkotte1, H D Schulte, W Bircks, B E Strauer.   

Abstract

Six hundred consecutive patients were operated on between September 1978 and October 1982 for isolated aortic (n = 298), mitral (n = 215), or multiple valve replacement (n = 87) with the St. Jude Medical bileaflet prosthesis. Mean age of the 303 female and 297 male patients was 50.7 +/- 9.6 (range 12 to 83) years. All patients were followed up prospectively; follow-up was complete and averaged 122.2 +/- 1.1 months for operative survivors. Total follow-up for aortic patients was 2904.1 patient-years, for mitral replacement 1859.5 patient-years, and for multiple valve replacement 736 patient-years. When the prothrombin times measured with different thromboplastins were converted into an international normalized ratio, four patient groups could be separated; that is, the groups comprised patients whose anticoagulation was maintained during the follow-up within an international normalized ratio corridor of 4.0 to 6.0, 3.0 to 4.5, 2.5 to 3.5, or 1.75 to 2.75. Less intensive anticoagulation in terms of the international normalized ratio values caused only a mild increase in the incidence of thromboembolic complications but a highly significant decrease in the rate of bleeding. Severe bleeding complications in the aortic valve group were highest with an international normalized ratio of 4.0 to 6.0 (1.15 per patient-year) and lowest with an international normalized ratio of 1.75 to 2.75 (0.24 per patient-year). The same held true for patients with single St. Jude Medical mitral valve replacement (2.09 per patient-year versus 0.72 per patient-year) and multiple valve replacements (4.45 per patient-year versus 1.20 per patient-year). These results suggest that the generally recommended international normalized ratio of 3.0 to 4.5 may be too high for patients with St. Jude Medical aortic valve replacement and also for patients with St. Jude Medical prostheses in the mitral position if, with respect to the thromboembolic hazard, there is not a predominating patient-related comorbidity. A large multicenter prospective randomized study is therefore proposed to establish the safe international normalized ratio levels accompanied by the lowest complication rates for both bleeding and thromboembolic events after St. Jude Medical prosthesis implantation (German experience with low intensity anticoagulation study).

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8159036

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  11 in total

1.  Successful reoperation after Batista partial left ventriculectomy demonstrates patient's hemodynamic recovery.

Authors:  O Taşdemir; D S Küçükaksu; O Tarcan; K Vural; E Sener
Journal:  Tex Heart Inst J       Date:  1999

Review 2.  [Modern aspects in the management of acquired heart valve lesions].

Authors:  D Horstkotte; H P Schultheiss
Journal:  Herz       Date:  1998-11       Impact factor: 1.443

3.  Evaluation of coagulant activity after mechanical heart valve replacement.

Authors:  Naoki Konagai; Norio Uchimura; Keita Nakamura; Tatsuhiko Kudo
Journal:  J Artif Organs       Date:  2006       Impact factor: 1.731

4.  Mitral valve replacement in children: mortality, morbidity, and haemodynamic status up to medium term follow up.

Authors:  C van Doorn; R Yates; V Tsang; M deLeval; M Elliott
Journal:  Heart       Date:  2000-12       Impact factor: 5.994

5.  Optimal Frequency of Patient Monitoring and Intensity of Oral Anticoagulation Therapy in Valvular Heart Disease.

Authors: 
Journal:  J Thromb Thrombolysis       Date:  1998-01       Impact factor: 2.300

Review 6.  Anticoagulation intensity and outcomes among patients prescribed oral anticoagulant therapy: a systematic review and meta-analysis.

Authors:  Natalie Oake; Alison Jennings; Alan J Forster; Dean Fergusson; Steve Doucette; Carl van Walraven
Journal:  CMAJ       Date:  2008-07-29       Impact factor: 8.262

7.  The effects of lower intensity anticoagulation therapy on coagulation system in patients with mechanical prosthetic valves.

Authors:  X Du; K Zhang; Z Hu; H Lan; J Luo; Y Jin
Journal:  J Tongji Med Univ       Date:  1999

Review 8.  Plasminogen activators and ischemic stroke: conditions for acute delivery.

Authors:  Gregory J del Zoppo
Journal:  Semin Thromb Hemost       Date:  2013-03-28       Impact factor: 4.180

9.  Relationship between the Occurrence of Thromboembolism and INR Measurement Interval in Low Intensity Anticoagulation after Aortic Mechanical Valve Replacement.

Authors:  Sangho Rhie; Jun Young Choi; In Seok Jang; Jong Woo Kim; Chung Eun Lee; Hyun Oh Park
Journal:  Korean J Thorac Cardiovasc Surg       Date:  2011-06-11

10.  Perioperative anticoagulation in patients with mechanical heart valves undergoing elective surgery: results of a survey conducted among Korean physicians.

Authors:  Doyeun Oh; Sehyun Kim; Chang Young Lim; Jong Seok Lee; Seonyang Park; David Garcia; Mark A Crowther; Walter Ageno
Journal:  Yonsei Med J       Date:  2005-02-28       Impact factor: 2.759

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.