Literature DB >> 8158793

Bladder pressure sensors in an animal model.

E L Koldewijn1, P E Van Kerrebroeck, E Schaafsma, H Wijkstra, F M Debruyne, G S Brindley.   

Abstract

Urinary incontinence due to detrusor hyperreflexia might be inhibited on demand if changes in bladder pressure could be detected by sensors and transferred into pudendal nerve electrostimulation. The aim of this study is to investigate how the bladder wall reacts on different sensor implants. Sensors were implanted in twelve goats. In group 1 (n = 8) real sensors were placed on the peritoneal surface of the bladder dome, between the peritoneum and the muscular layer, and between the cervix and bladder. In group 2 (n = 4), dummy sensors were placed between the mucosal and muscular layers. During follow-up as long as 25 months, urodynamic studies, radiographic control and urine cultures were done. In group 1, sensors placed between the peritoneum and muscular layer gave the best results. In group 2, 11 of the 12 sensors eroded. The authors conclude that implantation of sensors in the bladder wall is feasible.

Entities:  

Mesh:

Year:  1994        PMID: 8158793     DOI: 10.1016/s0022-5347(17)35264-3

Source DB:  PubMed          Journal:  J Urol        ISSN: 0022-5347            Impact factor:   7.450


  5 in total

1.  Proposed new bladder volume monitoring device based on impedance measurement.

Authors:  B Provost; M Sawan
Journal:  Med Biol Eng Comput       Date:  1997-11       Impact factor: 2.602

2.  Conditional Electrical Stimulation in Animal and Human Models for Neurogenic Bladder: Working Toward a Neuroprosthesis.

Authors:  C R Powell
Journal:  Curr Bladder Dysfunct Rep       Date:  2016-10-24

3.  Is submucosal bladder pressure monitoring feasible?

Authors:  Anisha S Basu; Steve Majerus; Elizabeth Ferry; Iryna Makovey; Hui Zhu; Margot S Damaser
Journal:  Proc Inst Mech Eng H       Date:  2018-01-29       Impact factor: 1.617

4.  A Polypyrrole-based Strain Sensor Dedicated to Measure Bladder Volume in Patients with Urinary Dysfunction.

Authors:  Sumitra Rajagopalan; Mohamad Sawan; Ebrahim Ghafar-Zadeh; Oumarou Savadogo; Vamsy P Chodavarapu
Journal:  Sensors (Basel)       Date:  2008-08-27       Impact factor: 3.576

5.  Minimizing a Wireless Passive LC-Tank Sensor to Monitor Bladder Pressure: A Simulation Study.

Authors:  Jacob Melgaard; Johannes J Struijk; Nico J M Rijkhoff
Journal:  J Med Biol Eng       Date:  2017-06-16       Impact factor: 1.553

  5 in total