Literature DB >> 8158104

Thirteen current anti-HIV-1/HIV-2 enzyme immunoassays: how accurate are they?

L McAlpine1, J Gandhi, J V Parry, P P Mortimer.   

Abstract

The sensitivity and specificity of 13 current anti-HIV-1/HIV-2 screening enzyme immunoassays (EIA) for the detection of anti-HIV in human serum or plasma were investigated by testing against a panel of 454 well-characterised serum or plasma specimens. The panel included specimens confirmed to contain anti-HIV-1 (n = 96), anti-HIV-2 (n = 26), or low levels of anti-HIV (n = 44) as well as specimens collected during HIV-1 seroconversion (n = 73). Specimens from unselected blood donors (n = 80) and samples from patients with a range of pathological conditions (n = 135) were also included. Observed sensitivities ranged from 96.9% (Biochrom, UBI, and Vironostika) to 100% (Biotest, Cambridge Biotech, IAF Biochem, Ortho, and Vidas). For the seroconversion specimens, Biotest, Cambridge Biotech, Ortho, and Vidas were most sensitive. Observed specificities ranged from 89.9% (UBI) to 100% (Biochrom and Ortho). One assay (Ortho HIV 1+2 EIA) achieved maximum sensitivity and specificity, and was one of four assays to detect anti-HIV-1 early in seroconversion. The accuracy of several of the other EIAs was also quite adequate, so additional factors such as convenience and cost can be considered when choosing an assay from the group evaluated.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8158104     DOI: 10.1002/jmv.1890420203

Source DB:  PubMed          Journal:  J Med Virol        ISSN: 0146-6615            Impact factor:   2.327


  4 in total

Review 1.  Detection of human immunodeficiency virus antibodies in oral fluids.

Authors:  R L Hodinka; T Nagashunmugam; D Malamud
Journal:  Clin Diagn Lab Immunol       Date:  1998-07

2.  Multicenter evaluation of the new automated Enzymun-Test Anti-HIV 1 + 2 + subtyp O.

Authors:  B Weber
Journal:  J Clin Microbiol       Date:  1998-02       Impact factor: 5.948

3.  Risk of human immunodeficiency virus (HIV) transmission by anti-HIV-negative blood components in Germany and Austria.

Authors:  D W Schwartz; G Simson; K Baumgarten; H Fabritz; J Riggert; H Neumeyer; W R Mayr; M Köhler
Journal:  Ann Hematol       Date:  1995-04       Impact factor: 3.673

4.  Why the C-statistic is not informative to evaluate early warning scores and what metrics to use.

Authors:  Santiago Romero-Brufau; Jeanne M Huddleston; Gabriel J Escobar; Mark Liebow
Journal:  Crit Care       Date:  2015-08-13       Impact factor: 9.097

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.