Mechanical forces as predictors of healing during tibial lengthening by distraction osteogenesis.

J Aronson1, J H Harp.   

Abstract

Direct axial loads were measured weekly during a 15% left tibial lengthening in 21 skeletally mature dogs using three in-line load cells mounted between the rings of an Ilizarov external fixator. The loads increased linearly over time to a maximum at the end of distraction (Week 4). The metaphyseal lengthening sites (mean, 155 N) generated significantly higher loads than diaphyseal sites (mean, 111 N). Stress was calculated by dividing measured load by the computed tomographic-measured cross-sectional area of each distraction osteogenesis site; the metaphyseal and diaphyseal groups demonstrated equal stress at each time point with a maximum of 47 N/cm2 at the end of distraction. Six premature consolidations occurred that demonstrated loads significantly greater than 200 N by Week 2 of distraction. Three nonunions occurred that had significantly lower loads measured by Week 3 of distraction (mean, 60 N or 26 N/cm2).

Entities:  

Mesh:

Year:  1994        PMID: 8156700

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  8 in total

1.  Analytical modelling of Kirschner wires in Ilizarov circular external fixator as pretensioned slender beams.

Authors:  A R Zamani; S O Oyadiji
Journal:  J R Soc Interface       Date:  2009-03-06       Impact factor: 4.118

2.  Outcome of a metaphyseal reverse total shoulder replacement in rheumatoid arthritis.

Authors:  P Consigliere; C Witney-Lagen; L Natera; G Sforza; J Bruguera; R Abraham; E Atoun; O Levy
Journal:  Musculoskelet Surg       Date:  2021-03-30

3.  Current concepts of leg lengthening.

Authors:  Carol C Hasler; Andreas H Krieg
Journal:  J Child Orthop       Date:  2012-03-21       Impact factor: 1.548

4.  The role of soft-tissue traction forces in bone segment transport for callus distraction : A force measurement cadaver study on eight human femora using a novel intramedullary callus distraction system.

Authors:  Konstantin Horas; Reinhard Schnettler; Gerrit Maier; Gaby Schneider; Uwe Horas
Journal:  Strategies Trauma Limb Reconstr       Date:  2015-03-28

Review 5.  The effect of altering the mechanical loading environment on the expression of bone regenerating molecules in cases of distraction osteogenesis.

Authors:  Mohammad M Alzahrani; Emad A Anam; Asim M Makhdom; Isabelle Villemure; Reggie Charles Hamdy
Journal:  Front Endocrinol (Lausanne)       Date:  2014-12-10       Impact factor: 5.555

6.  Distraction osteogenesis in dog with a tooth-borne device: Histological and histomorphometric analysis.

Authors:  Francisco Vale; Inês Francisco; João Cavaleiro; Francisco Caramelo; Adriana Guimarães; João Brochado
Journal:  J Clin Exp Dent       Date:  2020-01-01

7.  Distraction by a monotube fixator to achieve limb lengthening: predictive factors for tibia trauma.

Authors:  Olayinka O Adegbehingbe; Owolabi D Ojo; Paul O Abiola; Abimbola L Ariyibi; Lawrence M Oginni; John A Obateru
Journal:  J Trauma Manag Outcomes       Date:  2013-05-14

8.  Retraction of transporting bone segment during Ilizarov bone transport.

Authors:  Yunhong Ma; Qudong Yin; Yongwei Wu; Zongnan Wang; Zhenzhong Sun; Sanjun Gu; Yongjun Rui; Xiaofei Han
Journal:  BMC Musculoskelet Disord       Date:  2020-10-26       Impact factor: 2.362

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.