Literature DB >> 8154589

Prevention of the rapid degradation of subcutaneously implanted Ag/AgCl reference electrodes using polymer coatings.

F Moussy1, D J Harrison.   

Abstract

To assess the effect of the biological response to implanted Ag/AgCl reference electrodes on the electrode stability, uncoated and polymer-coated Ag/AgCl electrodes were implanted subcutaneously in rats. After 1 week of implantation, uncoated Ag/AgCl electrode potentials, measured in 0.1 M KCl, shifted by about -180 mV, and both voltammetry and electron microscopy showed that all the AgCl was removed. The electrodes could be significantly protected by coating with polyurethane or a perfluorinated ionomer (Nafion) cured at 120 degrees C for 1 h. Electron micrographs showed the 120 degrees C cured Nafion and polyurethane coatings remained intact over 2 weeks of implantation. Following 2 weeks of implantation the cured, Nafion-coated electrodes' potentials were shifted by -15 +/- 7 mV relative to the initial values. Voltammetry showed that they were still not polarizable. The current densities obtained with the coated reference electrodes are sufficient for their use as counter/pseudoreference electrodes with implantable two-electrode glucose sensor systems. The tissue response to coated electrodes was minimal in comparison to the response to uncoated reference electrodes.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8154589     DOI: 10.1021/ac00077a015

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  22 in total

1.  Hypersensitive glutamate signaling correlates with the development of late-onset behavioral morbidity in diffuse brain-injured circuitry.

Authors:  Theresa Currier Thomas; Jason M Hinzman; Greg A Gerhardt; Jonathan Lifshitz
Journal:  J Neurotrauma       Date:  2011-12-01       Impact factor: 5.269

2.  Chronically Implanted, Nafion-Coated Ag/AgCl Reference Electrodes for Neurochemical Applications.

Authors:  Parastoo Hashemi; Paul L Walsh; Thomas S Guillot; Julie Gras-Najjar; Pavel Takmakov; Fulton T Crews; R Mark Wightman
Journal:  ACS Chem Neurosci       Date:  2011-11-16       Impact factor: 4.418

3.  Background Signal as an in Situ Predictor of Dopamine Oxidation Potential: Improving Interpretation of Fast-Scan Cyclic Voltammetry Data.

Authors:  Carl J Meunier; James G Roberts; Gregory S McCarty; Leslie A Sombers
Journal:  ACS Chem Neurosci       Date:  2017-01-24       Impact factor: 4.418

4.  How to design a biosensor.

Authors:  W Kenneth Ward
Journal:  J Diabetes Sci Technol       Date:  2007-03

5.  Acute treatment with doxorubicin affects glutamate neurotransmission in the mouse frontal cortex and hippocampus.

Authors:  Theresa Currier Thomas; Joshua A Beitchman; Francois Pomerleau; Teresa Noel; Paiboon Jungsuwadee; D Allan Butterfield; Daret K St Clair; Mary Vore; Greg A Gerhardt
Journal:  Brain Res       Date:  2017-07-11       Impact factor: 3.252

6.  Failure of Standard Training Sets in the Analysis of Fast-Scan Cyclic Voltammetry Data.

Authors:  Justin A Johnson; Nathan T Rodeberg; R Mark Wightman
Journal:  ACS Chem Neurosci       Date:  2016-01-27       Impact factor: 4.418

7.  Mitigating the Effects of Electrode Biofouling-Induced Impedance for Improved Long-Term Electrochemical Measurements In Vivo.

Authors:  Blake T Seaton; Daniel F Hill; Stephen L Cowen; Michael L Heien
Journal:  Anal Chem       Date:  2020-04-16       Impact factor: 6.986

8.  Chronic microsensors for longitudinal, subsecond dopamine detection in behaving animals.

Authors:  Jeremy J Clark; Stefan G Sandberg; Matthew J Wanat; Jerylin O Gan; Eric A Horne; Andrew S Hart; Christina A Akers; Jones G Parker; Ingo Willuhn; Vicente Martinez; Scott B Evans; Nephi Stella; Paul E M Phillips
Journal:  Nat Methods       Date:  2009-12-27       Impact factor: 28.547

9.  Technological Barriers in the Use of Electrochemical Microsensors and Microbiosensors for in vivo Analysis of Neurological Relevant Substances.

Authors:  Bogdan Bucur
Journal:  Curr Neuropharmacol       Date:  2012-09       Impact factor: 7.363

Review 10.  Fully integrated biochip platforms for advanced healthcare.

Authors:  Sandro Carrara; Sara Ghoreishizadeh; Jacopo Olivo; Irene Taurino; Camilla Baj-Rossi; Andrea Cavallini; Maaike Op de Beeck; Catherine Dehollain; Wayne Burleson; Francis Gabriel Moussy; Anthony Guiseppi-Elie; Giovanni De Micheli
Journal:  Sensors (Basel)       Date:  2012-08-08       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.