Literature DB >> 8153926

Normal range for transdiaphragmatic pressures during sniffs with catheter mounted transducers.

S A Evans1, L Watson, A J Cowley, I D Johnston, W J Kinnear.   

Abstract

BACKGROUND: Transdiaphragmatic pressure (sniff PDI) during maximal sniffs is a useful clinical test of inspiratory muscle function. Although a normal range has been established for sniff PDI using air filled balloons, no comparable data are available for catheter mounted pressure transducers.
METHODS: Using a single catheter with two pressure transducers 15 cm apart, oesophageal and gastric pressures were recorded in 50 normal volunteers (25 women), five of each sex from each decade between the third and seventh decades of life. Each subject performed 10 maximal sniffs at functional residual capacity.
RESULTS: Mean (SD) sniff PDI was 149 (32) cm H2O in men and 127 (22) cm H2O in women. The lower limits of normal for sniff PDI (mean -1.96 x SD) after logarithmic transformation of the data were 95 and 78 cm H2O in men and women respectively.
CONCLUSIONS: With this technique transdiaphragmatic pressure can be measured using a single catheter which can easily be cleaned and reused. The values for sniff PDI are similar to those recorded previously with air filled balloons, suggesting that the method of recording pressure does not significantly affect the values obtained.

Entities:  

Mesh:

Year:  1993        PMID: 8153926      PMCID: PMC464665          DOI: 10.1136/thx.48.7.750

Source DB:  PubMed          Journal:  Thorax        ISSN: 0040-6376            Impact factor:   9.139


  16 in total

1.  IMPROVED TECHNIQUE FOR ESTIMATING PLEURAL PRESSURE FROM ESOPHAGEAL BALLOONS.

Authors:  J MILIC-EMILI; J MEAD; J M TURNER; E M GLAUSER
Journal:  J Appl Physiol       Date:  1964-03       Impact factor: 3.531

2.  A technique for measuring frequency response of pressure, volume, and flow transducers.

Authors:  A C Jackson; A Vinegar
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1979-08

3.  Dynamic characteristics of air-filled differential pressure transducers.

Authors:  P A Proulx; A Harf; H Lorino; G Atlan; D Laurent
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1979-03

4.  Maximal respiratory pressures: normal values and relationship to age and sex.

Authors:  L F Black; R E Hyatt
Journal:  Am Rev Respir Dis       Date:  1969-05

5.  Measurement of transdiaphragmatic pressure with a single gastric-esophageal probe.

Authors:  R Gilbert; D Peppi; J H Auchincloss
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1979-09

6.  Limitations of measurement of transdiaphragmatic pressure in detecting diaphragmatic weakness.

Authors:  A De Troyer; M Estenne
Journal:  Thorax       Date:  1981-03       Impact factor: 9.139

7.  Assessment of the catheter tip pressure transducer for use in infant lung function tests.

Authors:  C S Beardsmore; Y C Wong; J Stocks; M Silverman
Journal:  Med Biol Eng Comput       Date:  1982-11       Impact factor: 2.602

8.  Predicted normal values for maximal respiratory pressures in caucasian adults and children.

Authors:  S H Wilson; N T Cooke; R H Edwards; S G Spiro
Journal:  Thorax       Date:  1984-07       Impact factor: 9.139

9.  Inspiratory muscle force in normal subjects and patients with interstitial lung disease.

Authors:  A de Troyer; J C Yernault
Journal:  Thorax       Date:  1980-02       Impact factor: 9.139

10.  Respiratory pressures and function in young adults.

Authors:  J A Leech; H Ghezzo; D Stevens; M R Becklake
Journal:  Am Rev Respir Dis       Date:  1983-07
View more
  3 in total

1.  Static lung compliance in chronic heart failure: relation with dyspnoea and exercise capacity.

Authors:  S A Evans; L Watson; A J Cowley; I D Johnston; W J Kinnear
Journal:  Thorax       Date:  1995-03       Impact factor: 9.139

2.  Respiratory muscle strength in chronic heart failure.

Authors:  S A Evans; L Watson; M Hawkins; A J Cowley; I D Johnston; W J Kinnear
Journal:  Thorax       Date:  1995-06       Impact factor: 9.139

3.  Pressure measurement characteristics of a micro-transducer and balloon catheters.

Authors:  William MacAskill; Ben Hoffman; Michael A Johnson; Graham R Sharpe; Dean E Mills
Journal:  Physiol Rep       Date:  2021-04