Literature DB >> 8143007

Imaging evaluation of artificial nipples during bottle feeding.

A J Nowak1, W L Smith, A Erenberg.   

Abstract

OBJECTIVES: To determine whether real-time ultrasonography can be used to directly visualize artificial nipples in vivo while an infant is sucking, to compare deformation differences of the artificial nipple with the human nipple during sucking, and to compare the suck mechanism used by the infant with four types of artificial nipples.
DESIGN: Nonrandomized clinical study with a control group.
SETTING: University-affiliated teaching hospital in Iowa City, Iowa. PARTICIPANTS: A volunteer sample of 35 healthy infants 6 to 12 weeks of age. INTERVENTION: None. MEASUREMENTS/MAIN
RESULTS: Images produced by real-time ultrasound of infants during sucking using artificial nipples were measured to determine the percentage lengthening, the percentage lateral compression, and the percentage flattening of nipples. These results were compared with data obtained from studies using breast-fed infants. None of the artificial nipples lengthened like the human nipple. One artificial nipple was significantly more compressible than the human nipple and the remaining three artificial nipples.
CONCLUSION: Real-time ultrasonography can be used to visualize artificial nipples in vivo during sucking.

Entities:  

Mesh:

Year:  1994        PMID: 8143007     DOI: 10.1001/archpedi.1994.02170010042008

Source DB:  PubMed          Journal:  Arch Pediatr Adolesc Med        ISSN: 1072-4710


  4 in total

1.  Breast feeding, bottle feeding, and non-nutritive sucking; effects on occlusion in deciduous dentition.

Authors:  D Viggiano; D Fasano; G Monaco; L Strohmenger
Journal:  Arch Dis Child       Date:  2004-12       Impact factor: 3.791

2.  Mechanics of sucking: comparison between bottle feeding and breastfeeding.

Authors:  Angel Moral; Ignasi Bolibar; Gloria Seguranyes; Josep M Ustrell; Gloria Sebastiá; Cristina Martínez-Barba; Jose Ríos
Journal:  BMC Pediatr       Date:  2010-02-11       Impact factor: 2.125

3.  Pacifier Stiffness Alters the Dynamics of the Suck Central Pattern Generator.

Authors:  Emily Zimmerman; Steven M Barlow
Journal:  J Neonatal Nurs       Date:  2008-06

Review 4.  Bottle-feeding an infant feeding modality: An integrative literature review.

Authors:  Judith Kotowski; Cathrine Fowler; Christina Hourigan; Fiona Orr
Journal:  Matern Child Nutr       Date:  2020-01-06       Impact factor: 3.092

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.