Literature DB >> 8132983

A nosocomial pseudo-outbreak of Mycobacterium xenopi due to a contaminated potable water supply: lessons in prevention.

D H Sniadack1, S M Ostroff, M A Karlix, R W Smithwick, B Schwartz, M A Sprauer, V A Silcox, R C Good.   

Abstract

OBJECTIVES: To determine risk factors for Mycobacterium xenopi isolation in patients following a pseudo-outbreak of infection with the organism.
DESIGN: Retrospective cohort analysis of mycobacteriology laboratory specimen records and frequency-matched case-control study of hospital patients.
SETTING: General community hospital. PATIENTS: For the case-control study, 13 case patients and 39 randomly selected controls with mycobacterial cultures negative for M xenopi, frequency matched by specimen source, whose specimens were submitted from June 1990 through June 1991.
RESULTS: Between June 1990 and June 1991, M xenopi was isolated from 13 clinical specimens processed at a midwestern hospital, including sputum (n = 6), bronchial washings (2), urine (4), and stool (1). None of the patients with M xenopi-positive specimens had apparent mycobacterial disease, although five received antituberculosis drug therapy for a range of one to six months. Specimens collected in a nonsterile manner were more likely to grow the organism than those collected aseptically (3.1% versus 0, relative risk = infinity, P = 0.003). M xenopi isolation was attributed to exposure of clinical specimens to tap water, including rinsing of bronchoscopes with tap water after disinfection, irrigation with tap water during colonoscopy, gargling with tap water before sputum collection, and collecting urine in recently rinsed bedpans. M xenopi was isolated from tap water in 20 of 24 patient rooms tested, the endoscopy suite, and the central hot water mixing tank, but not from water in the microbiology laboratory. The pseudo-outbreak occurred following a decrease in the hot water temperature from 130 degrees F to 120 degrees F in 1989.
CONCLUSIONS: Maintenance of a higher water temperature and improved specimen collection protocols and instrument disinfection procedures probably would have prevented this pseudo-outbreak.

Entities:  

Mesh:

Year:  1993        PMID: 8132983     DOI: 10.1086/646656

Source DB:  PubMed          Journal:  Infect Control Hosp Epidemiol        ISSN: 0899-823X            Impact factor:   3.254


  3 in total

1.  Genus level identification of mycobacteria from clinical specimens by using an easy-to-handle Mycobacterium-specific PCR assay.

Authors:  F Stauffer; H Haber; A Rieger; R Mutschlechner; P Hasenberger; V J Tevere; K K Young
Journal:  J Clin Microbiol       Date:  1998-03       Impact factor: 5.948

Review 2.  Transmission of infection by flexible gastrointestinal endoscopy and bronchoscopy.

Authors:  Julia Kovaleva; Frans T M Peters; Henny C van der Mei; John E Degener
Journal:  Clin Microbiol Rev       Date:  2013-04       Impact factor: 26.132

3.  Evidence-based spectrum of antimicrobial activity for disinfection of bronchoscopes.

Authors:  Constanze Wendt; Birgit Kampf
Journal:  J Hosp Infect       Date:  2008-10       Impact factor: 3.926

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.