Literature DB >> 8130029

Changes in pulmonary venous flow pattern during early neonatal life.

Y Agata1, S Hiraishi, K Oguchi, M Nowatari, K Hiura, K Yashiro, T Shimoda.   

Abstract

OBJECTIVE: To investigate serial changes in the pattern of flow in the pulmonary vein during the early neonatal period.
METHODS: Pulsed Doppler echocardiography was used to measure flow in the right upper pulmonary vein in 26 normal newborn infants. Peak flow velocity during systole (S) and diastole (D) and flow velocity at indents between the systolic and diastolic fraction (O) and between the diastolic and systolic fraction (X) were measured 1, 4-8, 24, and 96 hours after birth. The heart rate and diameter of the ductus arteriosus were measured simultaneously.
RESULTS: Continuous and phasic high flow velocity waveforms were seen 1 and 4-8 hours after birth. The mean (SD) peak flow velocities of X, S, O, and D an hour after birth were 35.2 (13.6) cm/s, 73.1 (23.1) cm/s, 58.5 (20.5) cm/s, and 81.5 (19.2) cm/s respectively. There were significant decreases in X, S, O, and D by 24 hours of age (p < 0.01 v 1 hour after birth) to 8.1 (10.3) cm/s, 52.8 (18.0) cm/s, 38.6 (14.5) cm/s, and 54.4 (11.2) cm/s respectively. These results indicate intermittent flow in the pulmonary vein, with flow stopping between diastole and systole. These flow velocities, X, S, O, and D, correlated well with the diameter of the ductus arteriosus (r = 0.80 v X, r = 0.62 v S, r = 0.63 v O, r = 0.75 v D).
CONCLUSION: This serial study showed changes in normal pulmonary vein flow patterns during the early neonatal period. The continuous and high flow velocity waveform that was seen immediately after birth resembled the pattern of pulmonary vein flow seen in congenital pulmonary stenosis and in cases of acute volume overload. This waveform may reflect a sudden increase in pulmonary circulatory volume with additional left to right shunting through the ductus arteriosus in relatively hypoplastic pulmonary veins.

Entities:  

Mesh:

Year:  1994        PMID: 8130029      PMCID: PMC483642          DOI: 10.1136/hrt.71.2.182

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  20 in total

1.  Influence of loading conditions and contractile state on pulmonary venous flow. Validation of Doppler velocimetry.

Authors:  B D Hoit; Y Shao; M Gabel; R A Walsh
Journal:  Circulation       Date:  1992-08       Impact factor: 29.690

2.  Micropuncture measurement of lung microvascular pressure profile in 3- to 4-week-old rabbits.

Authors:  J U Raj; P Chen; L Navazo
Journal:  Pediatr Res       Date:  1986-11       Impact factor: 3.756

3.  Two-dimensional Doppler echocardiographic assessment of closure of the ductus arteriosus in normal newborn infants.

Authors:  S Hiraishi; H Misawa; K Oguchi; N Kadoi; K Saito; N Fujino; M Hojo; Y Horiguchi; K Yashiro
Journal:  J Pediatr       Date:  1987-11       Impact factor: 4.406

4.  Ductus arteriosus blood flow during first 48 hours of life.

Authors:  M R Drayton; R Skidmore
Journal:  Arch Dis Child       Date:  1987-10       Impact factor: 3.791

Review 5.  Cardiac tamponade and pericardial effusion: respiratory variation in transvalvular flow velocities studied by Doppler echocardiography.

Authors:  C P Appleton; L K Hatle; R L Popp
Journal:  J Am Coll Cardiol       Date:  1988-05       Impact factor: 24.094

6.  Pulsed Doppler assessment of pulmonary vein obstruction.

Authors:  J F Smallhorn; H Pauperio; L Benson; R M Freedom; R D Rowe
Journal:  Am Heart J       Date:  1985-08       Impact factor: 4.749

7.  Developmental considerations in neonatal failure.

Authors:  A M Rudolph
Journal:  Hosp Pract (Off Ed)       Date:  1985-01-15

8.  Pulsed Doppler echocardiography in the preoperative evaluation of total anomalous pulmonary venous connection.

Authors:  J F Smallhorn; R M Freedom
Journal:  J Am Coll Cardiol       Date:  1986-12       Impact factor: 24.094

9.  Pulsed Doppler echocardiographic assessment of extraparenchymal pulmonary vein flow.

Authors:  J F Smallhorn; R M Freedom; P M Olley
Journal:  J Am Coll Cardiol       Date:  1987-03       Impact factor: 24.094

10.  Microvascular pressures measured by micropipettes in isolated edematous rabbit lungs.

Authors:  J U Raj; R D Bland; S J Lai-Fook
Journal:  J Appl Physiol (1985)       Date:  1986-02
View more
  1 in total

1.  Velocity time integral for right upper pulmonary vein in VLBW infants with patent ductus arteriosus.

Authors:  Gianluca Lista; Silvia Bianchi; Savina Mannarino; Federico Schena; Francesca Castoldi; Mauro Stronati; Fabio Mosca
Journal:  Clinics (Sao Paulo)       Date:  2016-10-01       Impact factor: 2.365

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.