Literature DB >> 8126033

Macrophage/particle interactions: effect of size, composition and surface area.

A S Shanbhag1, J J Jacobs, J Black, J O Galante, T T Glant.   

Abstract

Particulate wear-debris are detected in histiocytes/macrophages of granulomatous tissues adjacent to loose joint prostheses. Such cell-particle interactions have been simulated in vitro by challenging macrophages with particles dosed according to weight percent, volume percent, and number of particles. Each of these dosage methods has inherent shortcomings due to varying size and density of challenging particles of different compositions. In this study we challenged P388D1 macrophages with titania and polystyrene particles (< 2 microns), with dosage based on the ratio of the surface area of the particles to the surface area of the cells. The effect of size and composition on (1) the bone resorbing activity, (2) fibroblast proliferation, and (3) secretion of IL-1 and PGE2 was determined. Macrophage response to particulate debris appears to be dependent on particle size, composition, and dose as given by surface area ratio. P388D1 macrophages challenged with titania particles released IL-1, but did not stimulate fibroblasts. Inhibition of macrophage DNA synthesis at higher surface area ratios suggests cell damage or death. Particle-stimulated cells increased bone resorption up to 125% of controls but released only basal levels of PGE2. Macrophages stimulated by wear particles are expected to synthesize numerous factors affecting events in the bone-implant interface. Using the concept of surface area ratio allows us to study and compare such cellular responses to wear particles in a standardized manner.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8126033     DOI: 10.1002/jbm.820280111

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  47 in total

1.  Inhibitory effect of (-)-epigallocatechin gallate on titanium particle-induced TNF-α release and in vivo osteolysis.

Authors:  Shan Jin; Ju Young Park; Jung Min Hong; Tae Ho Kim; Hong In Shin; Eui Kyun Park; Shin Yoon Kim
Journal:  Exp Mol Med       Date:  2011-07-30       Impact factor: 8.718

2.  Comparison of the response of three human monocytic cell lines to challenge with polyethylene particles of known size and dose.

Authors:  J B Matthews; T R Green; M H Stone; B M Wroblewski; J Fisher; E Ingham
Journal:  J Mater Sci Mater Med       Date:  2001-03       Impact factor: 3.896

3.  A novel technique for the detailed size characterization of wear debris.

Authors:  A P Elfick; S M Green; I M Pinder; A Unsworth
Journal:  J Mater Sci Mater Med       Date:  2000-05       Impact factor: 3.896

4.  Morphological and chemical characterization of microfabricated fibres for biological applications.

Authors:  J Gold; B Kasemo
Journal:  J Mater Sci Mater Med       Date:  1997-05       Impact factor: 3.896

5.  The effect of particle size and electrical charge on macrophage-osteoclast differentiation and bone resorption.

Authors:  A Sabokbar; R Pandey; N A Athanasou
Journal:  J Mater Sci Mater Med       Date:  2003-09       Impact factor: 3.896

6.  Optimized adenovirus-antibody complexes stimulate strong cellular and humoral immune responses against an encoded antigen in naive mice and those with preexisting immunity.

Authors:  Jin Huk Choi; Joe Dekker; Stephen C Schafer; Jobby John; Craig E Whitfill; Christopher S Petty; Eid E Haddad; Maria A Croyle
Journal:  Clin Vaccine Immunol       Date:  2011-11-16

7.  The John Charnley Award: an accurate and sensitive method to separate, display, and characterize wear debris: part 1: polyethylene particles.

Authors:  Fabrizio Billi; Paul Benya; Aaron Kavanaugh; John Adams; Edward Ebramzadeh; Harry McKellop
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

8.  [Bone defect adjusted strategy in revision arthroplasty of the hip : Wich implant in wich situation? Innovations and approved methods].

Authors:  B S Craiovan; J Grifka; A Keshmiri; B Moser; M Wörner; T Renkawitz
Journal:  Orthopade       Date:  2015-05       Impact factor: 1.087

Review 9.  Cytotoxic effects of submicron- and nano-scale titanium debris released from dental implants: an integrative review.

Authors:  Redouane Messous; Bruno Henriques; Hassan Bousbaa; Filipe S Silva; Wim Teughels; Júlio C M Souza
Journal:  Clin Oral Investig       Date:  2021-02-22       Impact factor: 3.573

10.  Integrin-directed modulation of macrophage responses to biomaterials.

Authors:  Toral D Zaveri; Jamal S Lewis; Natalia V Dolgova; Michael J Clare-Salzler; Benjamin G Keselowsky
Journal:  Biomaterials       Date:  2014-01-24       Impact factor: 12.479

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.