Literature DB >> 8122126

Application of convergent-beam collimation and simultaneous transmission emission tomography to cardiac single-photon emission computed tomography.

F L Datz1, G T Gullberg, G L Zeng, C H Tung, P E Christian, A Welch, R Clack.   

Abstract

Single-photon emission computed tomography (SPECT) is the most commonly performed imaging technique for perfusion studies of the heart and brain. However, these organs are much smaller than the crystal surface of gamma cameras. SPECT sensitivity and resolution can be improved by using fan- and cone-beam collimators to magnify the image of these organs over a larger portion of the crystal face. Special orbits and reconstruction algorithms must be used with convergent-beam acquisitions to prevent image distortion. Differential attenuation of source activity in the chest is one of the most vexing problems in cardiac SPECT, especially with Thallium-201. Multi-headed cameras equipped with convergent-beam collimators allow a transmission image to be obtained at the same time as emission images. Applying a transmission map of the chest attenuation values to the emission images produces a truer picture of source distribution in the heart. This article reviews the technical problems associated with convergent-beam geometry and simultaneous transmission emission tomography SPECT imaging of the heart.

Entities:  

Mesh:

Year:  1994        PMID: 8122126     DOI: 10.1016/s0001-2998(05)80247-8

Source DB:  PubMed          Journal:  Semin Nucl Med        ISSN: 0001-2998            Impact factor:   4.446


  6 in total

1.  Correction of partial volume effects in myocardial SPECT.

Authors:  B F Hutton; A Osiecki
Journal:  J Nucl Cardiol       Date:  1998 Jul-Aug       Impact factor: 5.952

Review 2.  Attenuation compensation for cardiac single-photon emission computed tomographic imaging: Part 1. Impact of attenuation and methods of estimating attenuation maps.

Authors:  M A King; B M Tsui; T S Pan
Journal:  J Nucl Cardiol       Date:  1995 Nov-Dec       Impact factor: 5.952

3.  Transmission-based scatter correction of 180 degrees myocardial single-photon emission tomographic studies.

Authors:  B F Hutton; A Osiecki; S R Meikle
Journal:  Eur J Nucl Med       Date:  1996-10

Review 4.  Where are we with nuclear medicine in pediatrics?

Authors:  H R Nadel
Journal:  Eur J Nucl Med       Date:  1995-12

5.  Redirection of client/server relationship of X Window system as a simple, low-cost, departmental picture archiving and communication system solution for nuclear medicine.

Authors:  F L Datz; D A Baune; P E Christian
Journal:  J Digit Imaging       Date:  1994-08       Impact factor: 4.056

Review 6.  Sex specific issues relating to nuclear cardiology.

Authors:  L L Johnson
Journal:  J Nucl Cardiol       Date:  1995 Jul-Aug       Impact factor: 5.952

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.