Literature DB >> 8120546

Technetium 99m-labeled IMMU-4, a monoclonal antibody against carcinoembryonic antigen, for imaging of occult recurrent colorectal cancer in patients with rising serum carcinoembryonic antigen levels.

Y Z Patt1, D A Podoloff, S Curley, L Kasi, R Smith, V Bhadkamkar, C Charnsangavej.   

Abstract

PURPOSE: We tested whether nuclear imaging with technetium 99m-labeled murine monoclonal antibody (MoAb) against carcinoembryonic antigen (CEA) IMMU-4 will detect recurrent colorectal disease in patients with a rising serum CEA level but negative abdominal and pelvic computed tomographic (CT) scan, chest radiograph, and colonoscopy, or barium enema. PATIENTS AND METHODS: Sixteen patients with completely resected, CEA-producing colorectal cancer were given 1 mg of 99mTc-labeled IMMU-4 intravenously with no toxic side effects. Planar and single-photon emission CT (SPECT) scans were acquired at 6 hours. Fifteen patients underwent an exploratory laparotomy at 24 hours. Results of the scintigraphy were correlated with surgical findings.
RESULTS: Twelve of 15 patients (80%) had true-positive (TP) scans when correlated with surgery. Two of 15 (13%) had true-negative (TN) scans inasmuch as exploratory laparotomy failed to detect recurrent disease. A false-positive (FP) scan was obtained in one of 15 (7%). There were no false-negative (FN) scans. Sensitivity, specificity, accuracy, and the positive predictive value (PPV) were 100%, 67%, 93%, and 92%, respectively. Twenty-six histologically confirmed areas of malignancy were found and correlated with areas of increased activity seen on IMMU-4 scintigraphy. Twenty-one were TP; five were not detected by scintigraphy and were thus considered to be FN. There were five FP lesions and 25 TN regions. Sensitivity, specificity, accuracy, and the PPV in these 26 cancer tissues were 81%, 83%, 82%, and 81%, respectively. The median radioactivity ratio of tumorous tissue to normal tissue was 3.33, with a range of 0.89 to 17.16.
CONCLUSIONS: These results suggest that 99mTc IMMU-4 scintigraphy is an important addition to the armamentarium available for diagnostic imaging and may help detect occult metastatic cancer missed by abdominal and pelvic CT in patients with rising CEA levels.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8120546     DOI: 10.1200/JCO.1994.12.3.489

Source DB:  PubMed          Journal:  J Clin Oncol        ISSN: 0732-183X            Impact factor:   44.544


  3 in total

1.  Utility of FDG-PET for investigating unexplained plasma CEA elevation in patients with colorectal cancer.

Authors:  F L Flanagan; F Dehdashti; O A Ogunbiyi; I J Kodner; B A Siegel
Journal:  Ann Surg       Date:  1998-03       Impact factor: 12.969

2.  Radionuclide-Based Cancer Imaging Targeting the Carcinoembryonic Antigen.

Authors:  Hao Hong; Jiangtao Sun; Weibo Cai
Journal:  Biomark Insights       Date:  2008-09-23

3.  123I-labelled vasoactive intestinal peptide receptor scintigraphy in patients with colorectal cancer.

Authors:  M Raderer; A Kurtaran; M Hejna; F Vorbeck; P Angelberger; W Scheithauer; I Virgolini
Journal:  Br J Cancer       Date:  1998-07       Impact factor: 7.640

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.