Literature DB >> 8117860

Noninvasive measurement of medium-sized artery intima-media thickness in humans: in vitro validation.

X Girerd1, J J Mourad, C Acar, D Heudes, S Chiche, P Bruneval, J P Mignot, E Billaud, M Safar, S Laurent.   

Abstract

Recent research in ultrasound technology has led to the development of a high-resolution echo-tracking device. The present study was performed to evaluate the accuracy in the measurement of human radial artery intima-media thickness with this new device. We determined the correlation between histological and ultrasonic measurements of intima-media thickness in 15 radial artery segments obtained from the distal end of the wrist-elbow harvest for coronary bypass grafting in patients with coronary heart disease. For arterial intima-media thickness, a positive correlation was observed between ultrasonic and histological measurements (r = 0.618; p < 0.014), and the difference between ultrasound and histology measurements was 41 +/- 66 microns, with the higher measurements found by the ultrasonic device. In a subgroup of 11 patients, we determined the correlation between in vivo ultrasonic measurements of radial artery intima-media thickness at the preoperative stage and in vitro ultrasonic measurements of intima-media thickness obtained postoperatively in the same arterial segments. Internal diameter was larger in vivo than in vitro, and intima-media thickness was smaller in vivo than in vitro. The cross-sectional area of the arterial wall was calculated from internal diameter and intima-media thickness. In vitro wall cross-sectional area was correlated with in vivo wall cross-sectional area (r = 0.929; p < 0.0001). Repeatability of in vivo intima-media thickness measurements was investigated in 10 subjects through the calculation of the repeatability coefficient as defined by the British Standards Institution.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1994        PMID: 8117860     DOI: 10.1159/000159037

Source DB:  PubMed          Journal:  J Vasc Res        ISSN: 1018-1172            Impact factor:   1.934


  4 in total

1.  Elastic properties of peripheral arteries in heart failure patients in comparison with normal subjects.

Authors:  Chengyu Liu; Dingchang Zheng; Lina Zhao; Peng Li; Bin Li; Alan Murray; Changchun Liu
Journal:  J Physiol Sci       Date:  2013-03-22       Impact factor: 2.781

Review 2.  Relation between age and carotid artery intima-medial thickness: a systematic review.

Authors:  Inge C L van den Munckhof; Helen Jones; Maria T E Hopman; Jacqueline de Graaf; Jean Nyakayiru; Bart van Dijk; Thijs M H Eijsvogels; Dick H J Thijssen
Journal:  Clin Cardiol       Date:  2018-05-12       Impact factor: 2.882

3.  Targeted mutation of plakoglobin in mice reveals essential functions of desmosomes in the embryonic heart.

Authors:  P Ruiz; V Brinkmann; B Ledermann; M Behrend; C Grund; C Thalhammer; F Vogel; C Birchmeier; U Günthert; W W Franke; W Birchmeier
Journal:  J Cell Biol       Date:  1996-10       Impact factor: 10.539

4.  Decreased peripheral arterial volume distensibility in patients with branch retinal vein occlusion in comparison with normal subjects.

Authors:  Zhiqing Chen; Lingna Mao; Chengyu Liu; James R Blake; Dingchang Zheng
Journal:  Sci Rep       Date:  2014-10-20       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.