Literature DB >> 8113252

Migration of acetabular components, inserted with and without cement, in one-stage bilateral hip arthroplasty. A controlled, randomized study using roentgenstereophotogrammetric analysis.

I Onsten1, A S Carlsson, A Ohlin, J A Nilsson.   

Abstract

Twenty-one patients who had primary osteoarthrosis were managed with a bilateral total hip arthroplasty with insertion of a Charnley femoral component. In each patient, one hip was randomly allocated to have a Harris-Galante acetabular component inserted without cement, and the contralateral hip was treated with an all-polyethylene Charnley acetabular component fixed with cement. The clinical result was satisfactory in all patients. All forty-two hips were followed, with respect to migration of the acetabular component, with use of roentgenstereophotogrammetric analysis for a median of twenty-seven months (range, twenty-three to forty-nine months). Each patient served as his or her own control. Maximum migration in any direction was 1.7 and 2.1 millimeters, and maximum rotation was 2.2 and 2.0 degrees for the Harris-Galante and Charnley acetabular components, respectively. There was no significant difference in migration between the two designs of acetabular components (p = 0.98, p = 0.75, and p = 0.06 for the transverse, longitudinal, and sagittal axes, respectively). However, the Harris-Galante acetabular components rotated significantly more than the Charnley acetabular components around two of the three axes (p = 0.008, p = 0.08, and p = 0.03 for the transverse, longitudinal, and sagittal axes, respectively). The Charnley hip implant has been used clinically for a long time, with successful results. Comparison of new designs of implants with the Charnley prosthesis is therefore important. Roentgenstereophotogrammetric analysis provides a potential for detection of problems with fixation at an early stage rather than after long-term follow-up. No major difference in terms of skeletal fixation was found between the two designs of components after short to medium-term follow-up.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8113252     DOI: 10.2106/00004623-199402000-00004

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  7 in total

Review 1.  Is there evidence for a superior method of socket fixation in hip arthroplasty? A systematic review.

Authors:  Dean Pakvis; Gijs van Hellemondt; Enrico de Visser; Wilco Jacobs; Maarten Spruit
Journal:  Int Orthop       Date:  2011-03-15       Impact factor: 3.075

2.  Total Hip Arthroplasty Using Metal Head on a Highly Cross-linked Polyethylene Liner.

Authors:  Min-Yook Kim; Young-Yool Chung; Ji-Hoon Park; Jung-Ho Lee
Journal:  Hip Pelvis       Date:  2015-12-30

3.  No differences in outcomes between cemented and uncemented acetabular components after 12-14 years: results from a randomized controlled trial comparing Duraloc with Charnley cups.

Authors:  Kristian Bjørgul; Wendy M Novicoff; S T Andersen; K Brevig; F Thu; M Wiig; O Ahlund
Journal:  J Orthop Traumatol       Date:  2010-03-03

4.  Comparison of trabecular metal cups and titanium fiber-mesh cups in primary hip arthroplasty: a randomized RSA and bone mineral densitometry study of 50 hips.

Authors:  Thomas Baad-Hansen; Søren Kold; Poul Torben Nielsen; Mogens Berg Laursen; Poul Hedevang Christensen; Kjeld Soballe
Journal:  Acta Orthop       Date:  2011-03-25       Impact factor: 3.717

5.  Measurement of migration of a humeral head resurfacing prosthesis using radiostereometry without implant marking: an experimental study.

Authors:  Olof Sköldenberg; Magnus Odquist
Journal:  Acta Orthop       Date:  2011-03-24       Impact factor: 3.717

6.  Structural and Morselized Allografting Combined with a Cementless Cup for Acetabular Defects in Revision Total Hip Arthroplasty: A 4- to 14-Year Follow-Up.

Authors:  Hou-Tsung Chen; Cheng-Ta Wu; Tsan-Wen Huang; Hsin-Nung Shih; Jun-Wen Wang; Mel S Lee
Journal:  Biomed Res Int       Date:  2018-02-04       Impact factor: 3.411

Review 7.  Early proximal migration of cups is associated with late revision in THA: a systematic review and meta-analysis of 26 RSA studies and 49 survivalstudies.

Authors:  Bart G Pijls; Marc J Nieuwenhuijse; Marta Fiocco; Josepha Wm Plevier; Saskia Middeldorp; Rob Ghh Nelissen; Edward R Valstar
Journal:  Acta Orthop       Date:  2012-11-05       Impact factor: 3.717

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.