Literature DB >> 8112789

Metal release from titanium fixtures during placement in the mandible: an experimental study.

H Schliephake1, G Reiss, R Urban, F W Neukam, S Guckel.   

Abstract

Titanium screw taps and titanium fixtures were investigated by SEM before and after experimental use. Peri-implant bone surfaces were examined immediately after surgery and 5 months after implantation by SEM using the SE mode, backscattered electron imaging, and EDX analysis to detect titanium contamination of the bone specimens. The Ti content of the livers, kidneys, and lungs of six Göttingen minipigs, which had received two screw implants each, was determined using flameless atomic absorption spectroscopy and compared to a control group with no implants. Results showed that Ti particles were abraded and deposited on the bone surface during the preparation of implant beds. Five months after placement, particles were no longer observed on the bone surface next to the implants. Determination of the Ti concentration of the inner organs showed that the lungs contained the highest amount of titanium. The Ti content of the kidneys and livers was much lower. All values differed significantly from those of the control group (P < .01).

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8112789

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  18 in total

1.  The role of citrate, lactate and transferrin in determining titanium release from surgical devices into human serum.

Authors:  Justin P Curtin; Minji Wang; Tianfan Cheng; Lijian Jin; Hongzhe Sun
Journal:  J Biol Inorg Chem       Date:  2018-04-05       Impact factor: 3.358

2.  Dental implant surfaces after insertion in bone: an in vitro study in four commercial implant systems.

Authors:  Herbert Deppe; Carolina Wolff; Florian Bauer; Ricarda Ruthenberg; Anton Sculean; Thomas Mücke
Journal:  Clin Oral Investig       Date:  2017-10-24       Impact factor: 3.573

Review 3.  Diagnostic tests for titanium hypersensitivity in implant dentistry: a systematic review of the literature.

Authors:  Lena Katharina Müller-Heupt; Eik Schiegnitz; Sebahat Kaya; Elisabeth Jacobi-Gresser; Peer Wolfgang Kämmerer; Bilal Al-Nawas
Journal:  Int J Implant Dent       Date:  2022-07-11

Review 4.  Are clinical findings of systemic titanium dispersion following implantation explained by available in vitro evidence? An evidence-based analysis.

Authors:  Justin Paul Curtin; Minji Wang
Journal:  J Biol Inorg Chem       Date:  2017-05-17       Impact factor: 3.358

5.  Surface Damage on Dental Implants with Release of Loose Particles after Insertion into Bone.

Authors:  Plinio Senna; Altair Antoninha Del Bel Cury; Stephen Kates; Luiz Meirelles
Journal:  Clin Implant Dent Relat Res       Date:  2013-11-28       Impact factor: 3.932

6.  Bone tissue response to experimental zirconia implants.

Authors:  Ilja Mihatovic; Vladimir Golubovic; Jürgen Becker; Frank Schwarz
Journal:  Clin Oral Investig       Date:  2016-08-09       Impact factor: 3.573

7.  Titanium transport through the blood stream. An experimental study on rats.

Authors:  Daniel G Olmedo; Débora Tasat; María B Guglielmotti; Rómulo L Cabrini
Journal:  J Mater Sci Mater Med       Date:  2003-12       Impact factor: 3.896

8.  PIXE micro-beam mapping of metals in human peri-implant tissues.

Authors:  P Passi; A Zadro; S Galassini; P Rossi; G Moschini
Journal:  J Mater Sci Mater Med       Date:  2002-11       Impact factor: 3.896

9.  Response of osteoblast-like cells cultured on zirconia to bone morphogenetic protein-2.

Authors:  Seung-Hee Han; Kyoung-Hwa Kim; Jung-Seok Han; Ki-Tae Koo; Tae-Il Kim; Yang-Jo Seol; Yong-Moo Lee; Young Ku; In-Chul Rhyu
Journal:  J Periodontal Implant Sci       Date:  2011-10-31       Impact factor: 2.614

10.  Gene expression of MC3T3-E1 osteoblastic cells on titanium and zirconia surface.

Authors:  Soon-Hyun Gong; Heesu Lee; Ahran Pae; Kwantae Noh; Yong-Moon Shin; Jung-Haeng Lee; Yi-Hyung Woo
Journal:  J Adv Prosthodont       Date:  2013-11-28       Impact factor: 1.904

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.