Literature DB >> 810904

Atrioventricular valve replacement with the Hancock porcine xenograft: a five year clinical experience.

C L McIntosh, L L Michaelis, A G Morrow, S B Itscoitz, D R Redwood, S E Epstein.   

Abstract

Since July, 1970, 111 patients have undergone mitral and/or tricuspid valve replacement with a glutaraldehyde-fixed porcine xenograft mounted on a flexible stent; 41 of these patients also had aortic valve replacement with a Starr-Edwards or Bjork-Shiley valve, and 85 patients presently are alive. Cumulative follow-up totals 2,060 months, with 16 patients followed more than 4 years. Anticoagulants have not been administered postoperatively, and one patient has had a systemic embolus. Postoperative hemodynamic assessments have been carried out in 54 patients, and in either the mitral or tricuspid position the valve was shown to have good hydraulic function. Significant mitral regurgitation, secondary to prosthetic dysfunction, occurred in one patient 56 months following implantation. Progressive prosthetic stenosis has not occurred, and hemolysis or anemia of clinical significance has not been observed as a consequence of the use of the use of the xenograft. To date, these clinical and hemodynamic data indicate that the glutaraldehyde-fixed xenograft, mounted on a flexible stent, is the prosthesis of choice for mitral and tricuspid valve replacement.

Entities:  

Mesh:

Substances:

Year:  1975        PMID: 810904

Source DB:  PubMed          Journal:  Surgery        ISSN: 0039-6060            Impact factor:   3.982


  8 in total

1.  Studies of the modified venous allograft.

Authors:  L J Perloff; D T Rowlands; C F Barker
Journal:  Ann Surg       Date:  1977-08       Impact factor: 12.969

2.  Clinical and haemodynamic evaluation of mounted porcine heterograft in mitral position.

Authors:  L Cotter; H C Miller
Journal:  Br Heart J       Date:  1979-04

3.  Severe and early stenosis of porcine heterograft mitral valve.

Authors:  J C Forfar; L Cotter; G N Morritt
Journal:  Br Heart J       Date:  1978-10

4.  Thrombotic complications after valve replacement with porcine heterografts.

Authors:  R Hetzer; F Gerbode; W J Kerth; J D Hill; G M Adappa
Journal:  World J Surg       Date:  1979-08-31       Impact factor: 3.352

5.  Infective endocarditis due to Actinobacillus actinomycetemcomitans in a patient with a porcine prosthetic mitral valve.

Authors:  G Lalonde; R Hand
Journal:  Can Med Assoc J       Date:  1980-02-09       Impact factor: 8.262

6.  Severe late failure of a porcine xenograft mitral valve: clinical, echocardiographic, and pathological findings.

Authors:  G Crupi; D Gibson; B Heard; C Lincoln
Journal:  Thorax       Date:  1980-03       Impact factor: 9.139

7.  Echocardiographic assessment of left ventricular filling after mitral valve surgery.

Authors:  M G St John Sutton; T A Traill; A S Ghafour; D J Brown; D G Gibson
Journal:  Br Heart J       Date:  1977-12

8.  Harken caged-disc mitral valve replacement, 1969-1975: analysis of late mortality, thromboembolism, and valve failure.

Authors:  R J Gray; L S Czer; A Chaux; D Sethna; M DeRobertis; M Raymond; J M Matloff
Journal:  Tex Heart Inst J       Date:  1987-12
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.