Literature DB >> 8106891

A novel sensor for routine continuous spirometry of intubated patients.

P Meriläinen1, H Hänninen, L Tuomaala.   

Abstract

Measurement of gas flow and airway pressure at the Y-piece of an endotracheal tube provides valuable information about airway integrity and basic pulmonary function. We describe the working principle and design of the D-lite sensor (Datex Division, Instrumentarium Corporation, Helsinki, Finland), which, in a single, lightweight adapter piece, encloses flow, airway pressure, and sidestream gas measurement. The main emphasis in the design of this instrument was on reliable and accurate operation during continuous monitoring with exposure to humidity and mucus. Therefore, a robust flow-restrictor element with a pick-off arrangement resembling a Pitot tube was employed. This arrangement has nonlinear characteristics with potential difficulties in the measurement of small flows. However, these inherent drawbacks, together with compensations required because of varying gas fractions and pressure, can be handled by sophisticated computer algorithms at the host-monitor end (Capnomac Ultima [Datex Division, Instrumentarium Corporation, Helsinki, Finland]). Validation methods with main results and a brief review of applications are given.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8106891     DOI: 10.1007/bf01618680

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  12 in total

1.  Capnography does not reliably detect double-lumen endotracheal tube malplacement.

Authors:  J W de Vries; M C Haanschoten
Journal:  J Clin Monit       Date:  1992-07

2.  Continuous monitoring of the flow-volume loops and compliance during anesthesia.

Authors:  G I Bardoczky; A d'Hollander
Journal:  J Clin Monit       Date:  1992-07

3.  Evaluation of a hot-wire respiratory flowmeter for clinical applicability.

Authors:  I Yoshiya; Y Shimada; K Tanaka
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1979-11

Review 4.  Respiratory mechanics in anaesthesia.

Authors:  J Milic-Emili; F M Robatto; J H Bates
Journal:  Br J Anaesth       Date:  1990-07       Impact factor: 9.166

5.  An aid in the diagnosis of malpositioned double-lumen tubes.

Authors:  B A Simon; W E Hurford; P H Alfille; K Haspel; E C Behringer
Journal:  Anesthesiology       Date:  1992-05       Impact factor: 7.892

6.  Monitoring compliance: a sensitive indicator of change.

Authors:  L M Huffman
Journal:  AANA J       Date:  1992-06

Review 7.  AANA journal course: new technologies in anesthesia: update for nurse anesthetists--monitoring ventilation and compliance with Side Stream Spirometry.

Authors:  L M Huffman
Journal:  AANA J       Date:  1991-06

8.  An electronic respirometer.

Authors:  L A Cox; A P Almeida; J S Robinson; J K Horsley
Journal:  Br J Anaesth       Date:  1974-04       Impact factor: 9.166

9.  Ultrasonic measurement of respiratory flow.

Authors:  D I Plaut; J G Webster
Journal:  IEEE Trans Biomed Eng       Date:  1980-10       Impact factor: 4.538

10.  A modified Pitot tube for the accurate measurement of tidal volume in children.

Authors:  A R Wolf; G A Volgyesi
Journal:  Anesthesiology       Date:  1987-11       Impact factor: 7.892

View more
  4 in total

1.  Disposable D-Lite sensors.

Authors:  T F McLoughlin; C S Hopkins
Journal:  J Clin Monit Comput       Date:  2014-03-09       Impact factor: 2.502

2.  Evaluation of a Pitot type spirometer in helium/oxygen mixtures.

Authors:  S Søndergaard; S Kárason; S Lundin; O Stenqvist
Journal:  J Clin Monit Comput       Date:  1998-08       Impact factor: 2.502

3.  Differential Pressure Spirometry for Mechanical Ventilation Using Dichotomic Search.

Authors:  Noe A Rodriguez-Olivares; Luciano Nava-Balanzar; Leonardo Barriga-Rodriguez
Journal:  IEEE Trans Instrum Meas       Date:  2021-09-29       Impact factor: 4.016

4.  Changes in respiratory compliance at laparoscopy: measurements using side stream spirometry.

Authors:  M Oikkonen; M Tallgren
Journal:  Can J Anaesth       Date:  1995-06       Impact factor: 5.063

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.