Literature DB >> 8094098

Spark erosion procedure: a method for extensive combined fixed and removable prosthodontic care.

H Weber1, G Frank.   

Abstract

Restoration that uses a combination of fixed and removable partial dentures, which involves precision attachments and telescopic procedures, represents one of the highest levels of functional and esthetic therapy. In the past, these restorations were mostly made with high gold-content alloys. The dental spark erosion procedure offers a sophisticated method for using base metal alloys for these complex restorations. This procedure combines the functional and esthetic advantages of precision restorations with the advantageous properties of base metal alloys such as low thermal conductivity, high strength, and lower cost.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8094098     DOI: 10.1016/0022-3913(93)90144-d

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  7 in total

1.  Retention force of removable partial dentures with different double crowns.

Authors:  Christin Arnold; Jeremias Hey; Jürgen M Setz; Arne F Boeckler; Ramona Schweyen
Journal:  Clin Oral Investig       Date:  2017-11-03       Impact factor: 3.573

2.  Multitechnique characterization of CPTi surfaces after electro discharge machining (EDM).

Authors:  Spiros Zinelis; Youssef S Al Jabbari; Andrew Thomas; Nick Silikas; George Eliades
Journal:  Clin Oral Investig       Date:  2013-03-17       Impact factor: 3.573

3.  Telescopic overdenture: Perio-prostho concern for advanced periodontitis.

Authors:  Roma Goswami; Puneet Mahajan; Amit Siwach; Ankur Gupta
Journal:  Contemp Clin Dent       Date:  2013-07

4.  Prosthetic Rehabilitation of Mandibular Defects with Fixed-removable Partial Denture Prosthesis Using Precision Attachment: A Twin Case Report.

Authors:  Vimal Kantilal Munot; Ramesh P Nayakar; Raghunath Patil
Journal:  Contemp Clin Dent       Date:  2017 Jul-Sep

5.  Clinical outcomes of rigid and non-rigid telescopic double-crown-retained removable dental prostheses: An analytical review.

Authors:  Jeong-Gyo Seo; Jin-Hyun Cho
Journal:  J Adv Prosthodont       Date:  2020-02-20       Impact factor: 1.904

6.  Rehabilitation of a maxillary partial edentulous patient using an implant-supported overdenture retained with two bilateral milled bars.

Authors:  Atif Mohammed Almadani; Fabian Huettig
Journal:  BMJ Case Rep       Date:  2020-08-24

7.  Effect of Laser Etching and Spark Erosion on Retention and Resistance of Partial Veneer Crown Copings Luted with Adhesive Resin Cement.

Authors:  Chandra Govindaraj Sarath; Sivanesan Karthikeyan Jagdish; Krishnan Murugesan; Balasubramaniam Muthukumar
Journal:  Contemp Clin Dent       Date:  2018-09
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.