Performance of a patient-dedicated, on-demand blood gas monitor in medical ICU patients.

C K Mahutte1, S A Sasse, P A Chen, M Holody.   

Abstract

We examined the performance characteristics of a new bedside blood gas monitor. This monitor's fluorescent pH, PCO2, and PO2 sensors are embedded in a cassette, which is calibrated in vitro and then inserted into the patient's radial artery tubing set. In 50 medical ICU patients, 683 paired monitor and conventional blood gas analyzer values were obtained. Performance was assessed via calculations of bias (mean monitor and analyzer difference) and its standard deviation (SD), plots of monitor and analyzer differences against the means (of monitor and analyzer), and linear regression analysis of the sequential changes in monitor values versus the corresponding sequential changes in analyzer values. The ex vivo calibration, assessed using the initial paired blood samples, showed a bias +/- SD of 0.02 +/- 0.02 for pH, -0.1 +/- 1.9 mm Hg for PCO2, and 4.3 +/- 6.0 mm Hg for PO2. For all paired samples (n = 683), the biases +/- SD were 0.004 +/- 0.023 for pH, 0.6 +/- 2.4 mm Hg for PCO2, and 2.7 +2- 6.4 mm HG for PO2. The PO2 bias increased as PO2 increased. The standard deviations (imprecision) of both PCO2 and PO2 also increased as the magnitudes of these variables increased. Sequential changes in monitor values versus the corresponding sequential changes in analyzer values revealed regression lines close to the line of identity. Serum sodium had no effect on pH bias. Daily drift of the sensors was inconsequential, with values of -0.01/d for pH, 1.7 mm Hg/d for PCO2, and 1.1 mm Hg/d for PO2. We conclude that the performance of this monitor is comparable to that of conventional blood gas analyzers.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8087363     DOI: 10.1164/ajrccm.150.3.8087363

Source DB:  PubMed          Journal:  Am J Respir Crit Care Med        ISSN: 1073-449X            Impact factor:   21.405


  8 in total

1.  Polarization sensing with visual detection.

Authors:  I Gryczynski; Z Gryczynski; J R Lakowicz
Journal:  Anal Chem       Date:  1999-04-01       Impact factor: 6.986

2.  Anisotropy-based sensing with reference fluorophores.

Authors:  J R Lakowicz; I Gryczynski; Z Gryczynski; J D Dattelbaum
Journal:  Anal Biochem       Date:  1999-02-15       Impact factor: 3.365

3.  Low-frequency modulation sensors using nanosecond fluorophores.

Authors:  J R Lakowicz; F N Castellano; J D Dattelbaum; L Tolosa; G Rao; I Gryczynski
Journal:  Anal Chem       Date:  1998-12-15       Impact factor: 6.986

4.  Sensing of carbon dioxide by a decrease in photoinduced electron transfer quenching.

Authors:  P Herman; Z Murtaza; J R Lakowicz
Journal:  Anal Biochem       Date:  1999-07-15       Impact factor: 3.365

5.  Clinical evaluation of a continuous intra-arterial blood gas system in critically ill patients.

Authors:  E E Roupie; L Brochard; F J Lemaire
Journal:  Intensive Care Med       Date:  1996-11       Impact factor: 17.440

6.  Control of arterial PCO2 by somatic afferents in sheep.

Authors:  Philippe Haouzi; Bruno Chenuel
Journal:  J Physiol       Date:  2005-10-13       Impact factor: 5.182

7.  Assessment of a continuous blood gas monitoring system in animals during circulatory stress.

Authors:  Sandro Gelsomino; Roberto Lorusso; Ugolino Livi; Stefano Romagnoli; Salvatore Mario Romano; Rocco Carella; Fabiana Lucà; Giuseppe Billè; Francesco Matteucci; Attilio Renzulli; Gil Bolotin; Giuseppe De Cicco; Pierluigi Stefàno; Jos Maessen; Gian Franco Gensini
Journal:  BMC Anesthesiol       Date:  2011-01-11       Impact factor: 2.217

8.  Continuous assessment of arterial blood gases.

Authors: 
Journal:  Crit Care       Date:  1997       Impact factor: 9.097

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.