Literature DB >> 8087038

Image reconstruction using non-adjacent drive configurations.

N J Avis1, D C Barber.   

Abstract

The standard 'back projection' image reconstruction algorithm developed at Sheffield uses data obtained by passing current between adjacent pairs of electrodes and measuring voltage differences between the remaining pairs. Previously it has been argued that this configuration gives the best resolution compared to all other bipolar drive configurations. However, it also gives the worst signal to noise ratio data and it is possible that under conditions of poor signal to noise ratio it may be advantageous to use an alternative drive configuration, even at the expense of resolution. A general image reconstruction algorithm for any bipolar drive configuration has been produced. Reconstruction algorithms for the adjacent, cross (drive electrodes 90 degrees apart) and polar drive (drive electrodes 180 degrees apart) have been examined and compared in terms of their resolution and noise performance.

Entities:  

Mesh:

Year:  1994        PMID: 8087038     DOI: 10.1088/0967-3334/15/2a/020

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  6 in total

1.  Model for the dielectric properties of human lung tissue against frequency and air content.

Authors:  P Nopp; N D Harris; T X Zhao; B H Brown
Journal:  Med Biol Eng Comput       Date:  1997-11       Impact factor: 2.602

Review 2.  Electrical impedance tomography: the holy grail of ventilation and perfusion monitoring?

Authors:  Steffen Leonhardt; Burkhard Lachmann
Journal:  Intensive Care Med       Date:  2012-09-20       Impact factor: 17.440

3.  Regional distribution of ventilation in patients with obstructive sleep apnea: the role of thoracic electrical impedance tomography (EIT) monitoring.

Authors:  Filippo Bongiovanni; Benedetta Mura; Chiara Tagliaferri; Alessandra Bisanti; Elisa Testani; Riccardo Maviglia; Giacomo Della Marca
Journal:  Sleep Breath       Date:  2016-05-03       Impact factor: 2.816

4.  Measurement-Based Domain Parameter Optimization in Electrical Impedance Tomography Imaging.

Authors:  Jan Dusek; Jan Mikulka
Journal:  Sensors (Basel)       Date:  2021-04-03       Impact factor: 3.576

Review 5.  A Review of EMG-, FMG-, and EIT-Based Biosensors and Relevant Human-Machine Interactivities and Biomedical Applications.

Authors:  Zhuo Zheng; Zinan Wu; Runkun Zhao; Yinghui Ni; Xutian Jing; Shuo Gao
Journal:  Biosensors (Basel)       Date:  2022-07-12

6.  Optimal Implementation Parameters of a Nonlinear Electrical Impedance Tomography Method Using the Complete Electrode Model.

Authors:  Jeongwoo Park; Jun Won Kang; Eunsoo Choi
Journal:  Sensors (Basel)       Date:  2022-09-03       Impact factor: 3.847

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.