A novel saturation transfer contrast method for 3D time-of-flight magnetic resonance angiography: a slice-selective off-resonance sinc pulse (SORS) technique.

M Miyazaki1, F Kojima, N Ichinose, Y Onozato, H Igarashi.   

Abstract

Saturation transfer contrast (STC) techniques have been employed to decrease the signal intensity of observed water by saturating a broad proton component. The STC pulse, generally spatially nonselective, reduces the signal of brain background tissues as well as inflowing blood in 3D time-of-flight (TOF) angiography. We present a novel technique, a slice-selective off-resonance sinc pulse (SORS), which is employed to enhance inflowing blood and to suppress the signal of stationary background tissues. The STC effects of the SORS and other spatially nonselective methods influencing inflowing blood is discussed in detail. Angiograms using the SORS method are also presented to demonstrate improved vessel conspicuity. In addition, the SORS method is applicable to imagers with a whole-body RF transmitter system.

Entities:  

Mesh:

Year:  1994        PMID: 8084237     DOI: 10.1002/mrm.1910320108

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  5 in total

1.  Pseudostenosis of the internal carotid artery in 3D time-of-flight MR angiography: effects of a magnetization transfer contrast pulse and metallic material.

Authors:  Shinji Naganawa; Tokiko Koshikawa; Kimihide Sato; Toshio Katagiri; Takeo Mimura; Takeo Ishigaki; Ikuo Aoki
Journal:  Eur Radiol       Date:  2003-04-10       Impact factor: 5.315

2.  Extensive pneumatized air cells causing susceptibility artifacts in the petrosus part of the ICA.

Authors:  M R McCoy; E Broussalis; M Killer; J Steinbacher; F Klausner
Journal:  Clin Neuroradiol       Date:  2015-05-05       Impact factor: 3.649

3.  Magnetization transfer by simple sequences of rectangular pulses.

Authors:  J Forster; F Schick; M Pfeffer; O Lutz
Journal:  MAGMA       Date:  1995-07       Impact factor: 2.310

4.  Contrast enhancement in TOF cerebral angiography at 7 T using saturation and MT pulses under SAR constraints: impact of VERSE and sparse pulses.

Authors:  Sebastian Schmitter; Michael Bock; Sören Johst; Edward J Auerbach; Kâmil Uğurbil; Pierre-François Van de Moortele
Journal:  Magn Reson Med       Date:  2011-12-02       Impact factor: 4.668

5.  Z-Spectrum analysis provides proton environment data (ZAPPED): a new two-pool technique for human gray and white matter.

Authors:  Mitsue Miyazaki; Cheng Ouyang; Xiangzhi Zhou; James B Murdoch; Yasutaka Fushimi; Tomohisa Okada; Koji Fujimoto; Aki Kido; Yoshiki Arakawa; Susumu Miyamoto; Kaori Togashi
Journal:  PLoS One       Date:  2015-03-13       Impact factor: 3.240

  5 in total