Literature DB >> 8081407

Effects of electrode size on basic excitatory responses and on selected stimulus parameters.

G Alon1, G Kantor, H S Ho.   

Abstract

Recent data have implicated the size of surface electrodes as an important factor affecting peripheral nerve excitation. Therefore, we studied the effects of electrode size on the basic excitatory responses and on stimulus characteristics. Four different sizes of self-adhesive surface electrodes were applied over the medial and lateral gastrocnemius muscle of 20 healthy subjects. The excitatory levels were sensory threshold, motor threshold, pain threshold, and maximally tolerated painful stimulation. Stimulus parameters included a symmetric biphasic waveform, 200 microseconds phase duration, and a pulse repetition rate of 50 pps. Amplitude was increased until the appropriate excitatory response was achieved. At this amplitude level, the computerized recording system collected data of stimulus peak current, peak voltage, and phase charge as well as isometric plantar flexion force. Repeated measure analysis of variance and Newman-Keuls post hoc tests revealed that increasing electrode size significantly decreased voltage but increased current and phase charge magnitudes. With increasing electrode area, the ratios of voltage/current decreased nonlinearly, while the ratios of charge/voltage increased nonlinearly. The comfort of stimulation for the same amount of plantar flexion force improved significantly as electrode size became larger. We concluded that electrode size affects the stimulus parameters, comfort, and force generation associated with electrically induced excitatory responses. Electrode size should be considered an integral part of the attempt to improve subject response to transcutaneous electrical stimulation.

Entities:  

Mesh:

Year:  1994        PMID: 8081407     DOI: 10.2519/jospt.1994.20.1.29

Source DB:  PubMed          Journal:  J Orthop Sports Phys Ther        ISSN: 0190-6011            Impact factor:   4.751


  9 in total

Review 1.  TENS: a treatment option for bladder dysfunction.

Authors:  S E Bristow; S T Hasan; D E Neal
Journal:  Int Urogynecol J Pelvic Floor Dysfunct       Date:  1996

2.  Critique of 'control of arterial Pco2 by somatic afferents'.

Authors:  Yunguo Yu; Chi-Sang Poon
Journal:  J Physiol       Date:  2006-05-01       Impact factor: 5.182

Review 3.  Is high-frequency neuromuscular electrical stimulation a suitable tool for muscle performance improvement in both healthy humans and athletes?

Authors:  Julien Gondin; Patrick J Cozzone; David Bendahan
Journal:  Eur J Appl Physiol       Date:  2011-09-10       Impact factor: 3.078

4.  The role of agonist and antagonist muscles in explaining isometric knee extension torque variation with hip joint angle.

Authors:  Theodoros M Bampouras; Neil D Reeves; Vasilios Baltzopoulos; Constantinos N Maganaris
Journal:  Eur J Appl Physiol       Date:  2017-08-12       Impact factor: 3.078

5.  Effect of Athletic Training on Fatigue During Neuromuscular Electrical Stimulation.

Authors:  Thomas J Abitante; Seward B Rutkove; Kevin R Duda; Dava J Newman
Journal:  Front Sports Act Living       Date:  2022-06-14

6.  A Comparison of Neuromuscular Electrical Stimulation Parameters for Postoperative Quadriceps Strength in Patients After Knee Surgery: A Systematic Review.

Authors:  Caitlin E W Conley; Carl G Mattacola; Kate N Jochimsen; Emily V Dressler; Christian Lattermann; Jennifer S Howard
Journal:  Sports Health       Date:  2021-01-11       Impact factor: 3.843

7.  Comparison of Proximally Versus Distally Placed Spatially Distributed Sequential Stimulation Electrodes in a Dynamic Knee Extension Task.

Authors:  Marco Laubacher; Efe A Aksöz; Stuart Binder-Macleod; Kenneth J Hunt
Journal:  Eur J Transl Myol       Date:  2016-06-13

8.  Effects of electrode size and placement on comfort and efficiency during low-intensity neuromuscular electrical stimulation of quadriceps, hamstrings and gluteal muscles.

Authors:  J Flodin; R Juthberg; P W Ackermann
Journal:  BMC Sports Sci Med Rehabil       Date:  2022-01-16

9.  Power output and fatigue properties using spatially distributed sequential stimulation in a dynamic knee extension task.

Authors:  Marco Laubacher; Anil Efe Aksöz; Robert Riener; Stuart Binder-Macleod; Kenneth J Hunt
Journal:  Eur J Appl Physiol       Date:  2017-07-03       Impact factor: 3.078

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.