Literature DB >> 8079970

Acute effects of different concentrations of dialysate magnesium during high-efficiency dialysis.

J Kelber1, E Slatopolsky, J A Delmez.   

Abstract

It has been suggested that magnesium carbonate (MgCO3) may be an effective and safe alternative to calcium carbonate in binding phosphorus in dialysis patients. In these studies, the concentration of magnesium in the dialysate was either very low or zero. To date, only patients undergoing conventional dialysis have been reported. The primary purpose of the present study was to determine the fluxes of magnesium using dialysate magnesium concentrations of 0 mg/dL, 0.6 mg/dL, and 1.8 mg/dL in eight patients undergoing high-efficiency hemodialysis. The net removal of magnesium was 486 +/- 44 mg, 306 +/- 69 mg, and 56 +/- 50 mg, with the use of dialysate magnesium concentrations of 0 mg/dL, 0.6 mg/dL, and 1.8 mg/dL, respectively (P = 0.001). Plasma magnesium levels significantly decreased from 3.3 +/- 0.2 mg/dL to 1.6 +/- 0.2 mg/dL and from 3.4 +/- 0.3 mg/dL to 2.1 +/- 0.2 mg/dL during the dialysis sessions using 0 mg/dL and 0.6 mg/dL magnesium dialysates, respectively. Plasma magnesium remained unchanged when 1.8 mg/dL dialysate magnesium was used. A significant independent correlation was found between the total magnesium removed and both the dialysate concentration used (P < 0.001) and the predialysis plasma magnesium level (P < 0.001). The measured magnesium removal exceeded the estimated predialysis extracellular fluid (ECF) magnesium pool with the use of magnesium-free dialysate. This was not found with dialysate magnesium concentrations of either 0.6 mg/dL or 1.8 mg/dL. A secondary purpose of the study was to determine the acute clinical tolerance of the low and magnesium-free dialysates.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8079970     DOI: 10.1016/s0272-6386(12)80902-4

Source DB:  PubMed          Journal:  Am J Kidney Dis        ISSN: 0272-6386            Impact factor:   8.860


  10 in total

1.  Magnesium Concentration in Dialysate: Is Higher Better?

Authors:  Jürgen Floege
Journal:  Clin J Am Soc Nephrol       Date:  2018-08-21       Impact factor: 8.237

2.  Fatal hypermagnesemia induced by preoperative colon preparation in an elderly woman: report of a case.

Authors:  Chieko Uchiyama; Takeshi Kato; Kodo Tomida; Rei Suzuki; Ken Nakata; Michiko Hamanaka; Takashi Kanemura; Masaaki Izumi; Shigeyuki Tamura
Journal:  Clin J Gastroenterol       Date:  2013-01-25

3.  The effect of different dialysate magnesium concentrations on QTc dispersion in hemodialysis patients.

Authors:  Farsad Afshinnia; Hardik Doshi; Panduranga S Rao
Journal:  Ren Fail       Date:  2012-02-02       Impact factor: 2.606

Review 4.  A Higher Concentration of Dialysate Magnesium to Reduce the Frequency of Muscle Cramps: A Narrative Review.

Authors:  Akshay Varghese; Eduardo Lacson; Jessica M Sontrop; Rey R Acedillo; Ahmed A Al-Jaishi; Sierra Anderson; Amit Bagga; Katie L Bain; Laura L Bennett; Clara Bohm; Pierre A Brown; Christopher T Chan; Brenden Cote; Varun Dev; Bonnie Field; Claire Harris; Shasikara Kalatharan; Mercedeh Kiaii; Amber O Molnar; Matthew J Oliver; Malvinder S Parmar; Melissa Schorr; Nikhil Shah; Samuel A Silver; D Michael Smith; Manish M Sood; Irina St Louis; Karthik K Tennankore; Stephanie Thompson; Marcello Tonelli; Hans Vorster; Blair Waldvogel; James Zacharias; Amit X Garg
Journal:  Can J Kidney Health Dis       Date:  2020-10-22

Review 5.  Dialysate Potassium, Dialysate Magnesium, and Hemodialysis Risk.

Authors:  Patrick H Pun; John P Middleton
Journal:  J Am Soc Nephrol       Date:  2017-10-09       Impact factor: 10.121

6.  Evaluation of calcium acetate/magnesium carbonate as a phosphate binder compared with sevelamer hydrochloride in haemodialysis patients: a controlled randomized study (CALMAG study) assessing efficacy and tolerability.

Authors:  Angel L M de Francisco; Michael Leidig; Adrian C Covic; Markus Ketteler; Ewa Benedyk-Lorens; Gabriel M Mircescu; Caecilia Scholz; Pedro Ponce; Jutta Passlick-Deetjen
Journal:  Nephrol Dial Transplant       Date:  2010-06-07       Impact factor: 5.992

7.  Magnesium in chronic kidney disease Stages 3 and 4 and in dialysis patients.

Authors:  John Cunningham; Mariano Rodríguez; Piergiorgio Messa
Journal:  Clin Kidney J       Date:  2012-02

8.  Lack of influence of serum magnesium levels on overall mortality and cardiovascular outcomes in patients with advanced chronic kidney disease.

Authors:  Olimpia Ortega; Isabel Rodriguez; Gabriela Cobo; Julie Hinostroza; Paloma Gallar; Carmen Mon; Milagros Ortiz; Juan Carlos Herrero; Cristina Di Gioia; Aniana Oliet; Ana Vigil
Journal:  ISRN Nephrol       Date:  2013-06-19

Review 9.  Optimizing haemodialysate composition.

Authors:  Francesco Locatelli; Vincenzo La Milia; Leano Violo; Lucia Del Vecchio; Salvatore Di Filippo
Journal:  Clin Kidney J       Date:  2015-08-08

10.  A neglected issue in dialysis practice: haemodialysate.

Authors:  Carlo Basile; Carlo Lomonte
Journal:  Clin Kidney J       Date:  2015-05-28
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.