Literature DB >> 8075994

Comparison of reversed and in situ saphenous vein grafts for infragenicular bypass: experience of two surgeons.

T Sasajima1, Y Kubo, M Kokubo, Y Izumi, M Inaba.   

Abstract

A series of 241 consecutive autogenous vein bypasses for chronic lower-limb ischaemia performed by two surgeons since 1980 was reviewed. After 1985, in situ vein bypass was employed preferentially and was compared with reversed vein bypass. The two groups of patients had similar risk factors, indications and outflow. Of the 241 bypasses, 157 were to the below-knee popliteal artery and 84 to infrapopliteal arteries. The utilization rates of a single ipsilateral saphenous vein were 57.5% for reversed and 71.9% for in situ vein bypass. However, in situ vein bypass was impossible in 43 procedures and these were changed to the reversed operation with contralateral vein. The primary 5-year patency rates of reversed and in situ vein bypass grafts to the popliteal artery were 82.5 versus 74.5%, and the primary 4-year patency rates for infrapopliteal bypass 68.5 versus 80.0%. The respective secondary patency rates were 94.2 versus 92.1% and 85.7 versus 91.1%. The main cause of graft failure was vein graft stenosis (reversed vein bypass, 13.0%; in situ, 11.1%), which usually occurred in the first 2 years after surgery. Of 23 grafts revised for stenosis, 21 were salvaged and restenosis rarely occurred. Both reversed and in situ vein bypass grafts were equally effective, but careful surveillance for 2 years and aggressive revision were extremely important after either type of reconstruction.

Entities:  

Mesh:

Year:  1993        PMID: 8075994

Source DB:  PubMed          Journal:  Cardiovasc Surg        ISSN: 0967-2109


  3 in total

1.  The results of in situ saphenous vein bypass for infrainguinal arterial reconstruction: Comparison between two types of valvulotomes.

Authors:  Yuichi Izumi; Katsuaki Magishi; Noriyuki Shimizu
Journal:  Int J Angiol       Date:  2010

2.  Surgical marking pen dye inhibits saphenous vein cell proliferation and migration in saphenous vein graft tissue.

Authors:  Shinsuke Kikuchi; Richard D Kenagy; Lu Gao; Thomas N Wight; Nobuyoshi Azuma; Michael Sobel; Alexander W Clowes
Journal:  J Vasc Surg       Date:  2015-04-30       Impact factor: 4.268

3.  Three-dimensional computed tomographic angiography in lower extremity revascularization.

Authors:  M Ishikawa; N Morimoto; T Sasajima; Y Kubo
Journal:  Surg Today       Date:  1999       Impact factor: 2.549

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.