Literature DB >> 8075522

Glutathione and cysteine measurement in biological samples by HPLC with a glassy carbon working detector.

F D Carvalho1, F Remião, P Vale, J A Timbrell, M L Bastos, M A Ferreira.   

Abstract

An HPLC method using a glassy carbon working detector for measuring cysteine and reduced glutathione (GSH) in biological samples was developed. Oxidized glutathione (GSSG) was also measured after reduction with glutathione reductase. This study was conducted in human plasma. Cysteine and GSH standard curves were linear in the physiological range, presenting detection limits of 22.0 pmol and 6.0 pmol respectively. Plasmatic results found were 43.92 +/- 4.15, 4.50 +/- 0.65, and 0.19 +/- 0.12 mM (means +/- SE), for cysteine, GSH and GSSG, respectively. Peak specificity for cysteine and reduced glutathione was certified by their disappearance after treatment with N-ethylmaleimide.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8075522     DOI: 10.1002/bmc.1130080308

Source DB:  PubMed          Journal:  Biomed Chromatogr        ISSN: 0269-3879            Impact factor:   1.902


  5 in total

1.  Electrochemical detection of glutathione using redox indicators.

Authors:  Eden Joy Pacsial-Ong; Robin L McCarley; Weihua Wang; Robert M Strongin
Journal:  Anal Chem       Date:  2006-11-01       Impact factor: 6.986

2.  Hepatoprotective activity of xanthones and xanthonolignoids against tert-butylhydroperoxide-induced toxicity in isolated rat hepatocytes--comparison with silybin.

Authors:  E R Fernandes; F D Carvalho; F G Remião; M L Bastos; M M Pinto; O R Gottlieb
Journal:  Pharm Res       Date:  1995-11       Impact factor: 4.200

3.  The use of screen-printed electrodes in a proof of concept electrochemical estimation of homocysteine and glutathione in the presence of cysteine using catechol.

Authors:  Patricia T Lee; Denise Lowinsohn; Richard G Compton
Journal:  Sensors (Basel)       Date:  2014-06-12       Impact factor: 3.576

4.  Electroanalytical Determination of Cysteine Using the Electrodes Based on Ternary Silver-Copper Sulfides.

Authors:  Nives Vladislavić; Ivana Škugor Rončević; Maša Buljac; Slobodan Brinić; Denis Krivić; Marijo Buzuk
Journal:  Sensors (Basel)       Date:  2018-11-02       Impact factor: 3.576

5.  A Novel Dicyanoisophorone-Based Ratiometric Fluorescent Probe for Selective Detection of Cysteine and Its Bioimaging Application in Living Cells.

Authors:  Hengrui Zhang; Nan Qin; Zhijie Fang
Journal:  Molecules       Date:  2018-02-22       Impact factor: 4.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.