Literature DB >> 8073462

Spatial distribution of carotid intimal-medial thickness as measured by B-mode ultrasonography.

M A Espeland1, H Hoen, R Byington, G Howard, W A Riley, C D Furberg.   

Abstract

BACKGROUND AND
PURPOSE: Measurements of intimal-medial thickness (IMT) of the carotid artery by B-mode ultrasonography are widely used as markers of atherosclerosis. This report describes empirical features of these measurements to characterize their distribution within arterial wall segments, to explore their potential as study outcome measures, and to examine their links with traditional risk factors for cardiovascular disease.
METHODS: Sequential transverse measurements of IMT in the carotid arteries were made in 899 participants from the Asymptomatic Carotid Artery Progression Study (ACAPS) at baseline. Data from 17 intrasegment sites in each of 12 arterial wall segments were used to describe patterns of thickness and visualization and to characterize cross-sectional area, severity, and roughness/irregularity by the intrasegment averages, maxima, and SDs of IMT, respectively.
RESULTS: Serial correlations of IMT measurements indicated localized and diffuse features of disease. The spatial distribution of IMT had two dominant features: overall mass and mass relative to roughness. The validity of these features was demonstrated by their correlation to known risk factors for carotid atherosclerosis: body mass index, age, high-density lipoprotein cholesterol, systolic blood pressure, smoking, and sex.
CONCLUSIONS: Both the mean and maxima of intrasegment measurements appear to be good candidates for use in clinical studies. B-mode ultrasonography has validity for the description of IMT roughness and shape. Both of these features are linked to cardiovascular risk factors, which supports the multifaceted nature of atherosclerosis.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8073462     DOI: 10.1161/01.str.25.9.1812

Source DB:  PubMed          Journal:  Stroke        ISSN: 0039-2499            Impact factor:   7.914


  7 in total

1.  Efficacy of 3-hydroxy-3-methylglutaryl coenzyme A reductase inhibitors for prevention of stroke.

Authors:  S Warshafsky; D Packard; S J Marks; N Sachdeva; D M Terashita; G Kaufman; K Sang; A J Deluca; S J Peterson; W H Frishman
Journal:  J Gen Intern Med       Date:  1999-12       Impact factor: 5.128

2.  Characteristics of carotid artery disease (CAD) and presenting cerebrovascular symptoms in an aged group.

Authors:  Qingwei Chen; Ying Liu; Linlin Pei; Dazhi Ke; Guiqiong Li; Wei Deng; Wuwei Yao
Journal:  Int J Cardiovasc Imaging       Date:  2008-10-14       Impact factor: 2.357

3.  The stiffness parameter β assessed by an ultrasonic phase-locked echo-tracking system is associated with plaque formation in the common carotid artery.

Authors:  Naohiro Ichino; Keisuke Osakabe; Keiko Sugimoto; Akira Yokoi; Takashi Inoue; Koji Suzuki; Yasuhiro Kusuhara; Nobuyuki Hamajima; Hiroji Takai; Tadayoshi Hata
Journal:  J Med Ultrason (2001)       Date:  2011-08-13       Impact factor: 1.314

4.  Biomarkers of subclinical atherosclerosis in patients with autoimmune disorders.

Authors:  Elisabetta Profumo; Manuela Di Franco; Brigitta Buttari; Roberta Masella; Carmelina Filesi; Maria Elena Tosti; Rossana Scrivo; Antongiulio Scarno; Antonio Spadaro; Luciano Saso; Rachele Riganò
Journal:  Mediators Inflamm       Date:  2012-02-22       Impact factor: 4.711

5.  KD Diagnosis Does Not Increase Cardiovascular Risk in Children According to Dynamic Intima-Media Roughness Measurements.

Authors:  Miriam König; Theresa Ullmann; Belén Pastor-Villaescusa; Robert Dalla-Pozza; Sarah Bohlig; Arno Schmidt-Trucksäss; Joseph Pattathu; Nikolaus A Haas; André Jakob
Journal:  J Clin Med       Date:  2022-02-22       Impact factor: 4.241

Review 6.  Carotid intima-media thickness studies: study design and data analysis.

Authors:  Sanne A E Peters; Michiel L Bots
Journal:  J Stroke       Date:  2013-01-31       Impact factor: 6.967

Review 7.  Carotid Intima-media Thickness Measurements: Relations with Atherosclerosis, Risk of Cardiovascular Disease and Application in Randomized Controlled Trials.

Authors:  Michiel L Bots; Gregory W Evans; Charles H Tegeler; Rudy Meijer
Journal:  Chin Med J (Engl)       Date:  2016-01-20       Impact factor: 2.628

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.