Literature DB >> 8067824

Aortic valve repair with fibrin glue for type A acute aortic dissection.

J R Séguin1, E Picard, J M Frapier, P A Chaptal.   

Abstract

Repair of the acute aortic insufficiency associated with type A aortic dissection is now preferred to valve replacement. This is generally achieved by resuspending the aortic valve using different types of suturing techniques, with sutures usually passing through the aortic wall, which causes bleeding at the suture sites. We suggest, instead, simply injecting fibrin glue between the two dissected layers of the aortic annulus, which achieves resuspension of the aortic valve and reinforces the proximal stump without the need for any sutures. To evaluate the efficacy of this simple technique, the cases of 15 consecutive patients who underwent operative intervention for the treatment of the type A aortic dissection associated with acute aortic insufficiency between January 1989 and July 1993 were reviewed. The mean patient age was 63 +/- 11.2 years (range, 43 to 74 years). All had massive 3+ or 4+ aortic insufficiency, documented pre-operatively by transesophageal echocardiography. None had any history of aortic regurgitation. In all patients, the aortic repair was done in conjunction with a supracoronary replacement of the ascending aorta with a collagen-impregnated graft attached using a running suture, after reinforcement of the dissected tissues with glue. There was one non-valve-related early death (6.7%) and no late mortality. At a mean follow-up of 2.3 years, all patients were in New York Heart Association functional class I and had a mean aortic insufficiency grade of 0.3 (range, 0 to 1+). Follow-up computed tomography in all patients showed closure of the dissecting process on the proximal ascending aorta.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8067824     DOI: 10.1016/0003-4975(94)92197-0

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  5 in total

1.  Experimental study on effective application of fibrin glue.

Authors:  Hajime Kin; Takayuki Nakajima; Hitoshi Okabayashi
Journal:  Gen Thorac Cardiovasc Surg       Date:  2012-03-15

Review 2.  An update on surgery for acute type A aortic dissection: aortic root repair, endovascular stent graft, and genetic research.

Authors:  Shinichi Suzuki; Munetaka Masuda
Journal:  Surg Today       Date:  2009-03-25       Impact factor: 2.549

Review 3.  The use of surgical glue in acute type A aortic dissection.

Authors:  Shinichi Suzuki; Munetaka Masuda; Kiyotaka Imoto
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-11-21

4.  Analysis of the hemostatic potential of modern topical sealants on arterial and venous anastomoses: an experimental porcine study.

Authors:  Hamidreza Fonouni; Arash Kashfi; Ali Majlesara; Oliver Stahlheber; Lukas Konstantinidis; Thomas W Kraus; Arianeb Mehrabi; Hani Oweira
Journal:  J Mater Sci Mater Med       Date:  2017-07-28       Impact factor: 3.896

Review 5.  Medical Adhesives and Their Role in Laparoscopic Surgery-A Review of Literature.

Authors:  Maciej Mazur; Wojciech Zakrzewski; Maria Szymonowicz; Zbigniew Rybak
Journal:  Materials (Basel)       Date:  2022-07-28       Impact factor: 3.748

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.