Literature DB >> 8067667

Elimination of bilirubin interference in creatinine assays by routine techniques: comparisons with a high performance liquid chromatography method.

S Boot1, N LaRoche, E F Legg.   

Abstract

The aim of this study was to find a method for creatinine analysis unaffected by jaundice by comparing four different methods with high performance liquid chromatography (HPLC) as a reference method. The methods investigated were Kodak DTSC single slide, Boehringer alkaline picrate with and without blank correction and a Boehringer enzymatic method, the last three using the Hitachi 737 analyser. HPLC results were compared with the results of the methods studied. In addition, graphs plotting the difference from the HPLC result against the bilirubin concentration were made; the ideal method would yield a slope and intercept of zero. While all methods showed a positive bias compared with HPLC, the Kodak slide and the Boehringer alkaline picrate with blank correction methods eliminated bilirubin interference and we have changed to the latter method as a consequence of this work.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8067667     DOI: 10.1177/000456329403100308

Source DB:  PubMed          Journal:  Ann Clin Biochem        ISSN: 0004-5632            Impact factor:   2.057


  6 in total

1.  Measurement of serum creatinine--current status and future goals.

Authors:  Michael Peake; Malcolm Whiting
Journal:  Clin Biochem Rev       Date:  2006-11

2.  Exogenous interferences with Jaffe creatinine assays: addition of sodium dodecyl sulfate to reagent eliminates bilirubin and total protein interference with Jaffe methods.

Authors:  P Srisawasdi; U Chaichanajarernkul; N Teerakanjana; S Vanavanan; M H Kroll
Journal:  J Clin Lab Anal       Date:  2010       Impact factor: 2.352

3.  Deproteinization of serum: another best approach to eliminate all forms of bilirubin interference on serum creatinine by the kinetic Jaffe reaction.

Authors:  P H Lolekha; S Jaruthunyaluck; P Srisawasdi
Journal:  J Clin Lab Anal       Date:  2001       Impact factor: 2.352

4.  Bilirubin Interference in Serum Creatinine Estimation by Jaffe's kinetic Method and Its Rectification in Three Different Kits.

Authors:  Prabhat Kumar Nigam
Journal:  Indian J Clin Biochem       Date:  2016-01-19

5.  Interference in autoanalyzer analysis.

Authors:  J J Fleming; S Swaminathan
Journal:  Indian J Clin Biochem       Date:  2001-01

6.  Frequency of icteric interference in clinical chemistry laboratory tests and causes of severe icterus.

Authors:  Sandhya Mainali; Anna E Merrill; Matthew D Krasowski
Journal:  Pract Lab Med       Date:  2021-10-23
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.