Literature DB >> 806658

A single radial haemolysis technique for the measurement of influenza antibody.

S M Russell, D McCahon, A S Beare.   

Abstract

A single radial haemolysis in geltechnique has been developed for the detection and measurement of antibody to influenza haemagglutinin. The methold combines the sensitivity of haemagglutination-inhibition with the accuracy of single radial diffusion. It is simple, quick, reproducible, does not require purified or concentrated virus, and is unaffected by non-specific inhibitors. The method is particularly suitable for the routine screening of large numbers of serum samples, and may have application also to viruses other than the influenza group.

Entities:  

Mesh:

Substances:

Year:  1975        PMID: 806658     DOI: 10.1099/0022-1317-27-1-1

Source DB:  PubMed          Journal:  J Gen Virol        ISSN: 0022-1317            Impact factor:   3.891


  41 in total

1.  Immunization of elderly volunteers with the 1988-89 inactivated whole influenza vaccine: assessment of antibody responses by haemagglutination inhibition and single radial haemolysis tests.

Authors:  A M Iorio; T Zei; M Neri; L Campitelli; M R Castrucci; I Donatelli
Journal:  Eur J Epidemiol       Date:  1992-07       Impact factor: 8.082

2.  Measurement of parainfluenza-3 virus antibody by the single radial hemolysis technique.

Authors:  M Probert; S M Russell
Journal:  J Clin Microbiol       Date:  1975-09       Impact factor: 5.948

3.  Quantitation of antibody to non-hemagglutinating viruses by single radial hemolysis: serological test for human coronaviruses.

Authors:  J C Hierholzer; G A Tannock
Journal:  J Clin Microbiol       Date:  1977-06       Impact factor: 5.948

4.  Single radial haemolysis for the detection of goat pox virus antigen and antibody.

Authors:  A K Tiwari; B S Negi
Journal:  Trop Anim Health Prod       Date:  1996-02       Impact factor: 1.559

5.  Comparative measurement of equine influenza virus antibodies in horse sera by single radial hemolysis, neutralization, and hemagglutination inhibition tests.

Authors:  H Yamagishi; T Nagamine; K Shimoda; S Ide; Y Igarashi; I Yoshioka; M Matumoto
Journal:  J Clin Microbiol       Date:  1982-04       Impact factor: 5.948

6.  Interpretation of responses and protective levels of antibody against attenuated influenza A viruses using single radial haemolysis.

Authors:  R Al-Khayatt; R Jennings; C W Potter
Journal:  J Hyg (Lond)       Date:  1984-10

7.  Evaluation of the single radial hemolysis test for measuring hemagglutinin- and neuraminidase-specific antibodies to H3N2 influenza strains and antibodies to influenza B.

Authors:  K Farrohi; F K Farrohi; G R Noble; H S Kaye; A P Kendal
Journal:  J Clin Microbiol       Date:  1977-03       Impact factor: 5.948

8.  Measurement of antibody to influenza virus neuraminidase by single radial hemolysis in agarose gels.

Authors:  K A Callow; A S Beare
Journal:  Infect Immun       Date:  1976-01       Impact factor: 3.441

9.  Single radial haemolysis: a survey of antibody titres in the highland region of Scotland to recent strains of influenza A.

Authors:  A W Joss; J K McPherson; H Williams
Journal:  J Hyg (Lond)       Date:  1978-02

10.  Determination of mumps and influenza antibodies by haemolysis-in-gel.

Authors:  P Väänänen; T Hovi; E P Helle; K Penttinen
Journal:  Arch Virol       Date:  1976       Impact factor: 2.574

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.