Literature DB >> 8064172

Increase in blood pressure reproducibility by repeated semi-automatic blood pressure measurements in the clinic environment.

G Mancia1, L Ulian, G Parati, S Trazzi.   

Abstract

OBJECTIVE: To evaluate whether increasing the number of blood pressure readings obtained in the clinic environment increases the blood pressure reproducibility. PATIENTS: Thirteen mild essential hypertensive patients studied in the outpatient clinics, following withdrawal of antihypertensive treatment for 4 weeks.
METHODS: The systolic and diastolic blood pressures were measured three times, using a mercury sphygmomanometer, with the patient in the sitting position. Measurements were then performed with the patient in the lying position using an oscillometric device (SpaceLabs 90202 or 90207). The device was operated semi-automatically at 3-min intervals until 25 readings had been collected. The same procedure was repeated 4 weeks later. The systolic blood pressure, diastolic blood pressure and heart rate were averaged by considering a progressively greater number of readings, from 1 to 25. The reciprocal of the standard deviation (1/SD) of the mean difference after 4 weeks was taken as the measure of reproducibility.
RESULTS: 1/SD increased progressively as the number of semi-automatic blood pressure readings from which the average was calculated increased. For a similar number of blood pressure readings the reproducibility was similar for semi-automatic readings to that for automatic readings obtained by 24-h ambulatory blood pressure monitoring.
CONCLUSION: Multiple blood pressure readings obtained semi-automatically in the outpatient clinics increase blood pressure reproducibility and make the value similar to that obtained by ambulatory blood pressure monitoring. The advantage of an increase in reproducibility for studies on antihypertensive drugs thus depends on the number of readings, and can also be obtained by semi-automatic measurements in the clinic environment.

Entities:  

Mesh:

Year:  1994        PMID: 8064172

Source DB:  PubMed          Journal:  J Hypertens        ISSN: 0263-6352            Impact factor:   4.844


  7 in total

1.  How many clinic BP readings are needed to predict cardiovascular events as accurately as ambulatory BP monitoring?

Authors:  K Eguchi; S Hoshide; K Shimada; K Kario
Journal:  J Hum Hypertens       Date:  2014-02-20       Impact factor: 3.012

2.  How many self-measured blood pressure readings are needed to estimate hypertensive patients' "true" blood pressure?

Authors:  M P García-Vera; J Sanz
Journal:  J Behav Med       Date:  1999-02

3.  Differences of blood pressure estimates between consecutive measurements on one occasion: implications for inter-study comparability of epidemiologic studies.

Authors:  M B Schulze; A Kroke; M M Bergmann; H Boeing
Journal:  Eur J Epidemiol       Date:  2000       Impact factor: 8.082

4.  [Accuracy and precision in blood pressure measurement. Comparative study of home self-measurement with measurement in the clinic and out-patient monitoring].

Authors:  J Divisón; A Puras; C Sanchis; L Artigao; J López Abril; E López De Coca; J Massó; B Rodríguez Paños
Journal:  Aten Primaria       Date:  2001-03-31       Impact factor: 1.137

5.  Guidelines for the design and conduct of human clinical trials on ingestion-time differences - chronopharmacology and chronotherapy - of hypertension medications.

Authors:  Ramón C Hermida; Michael H Smolensky; Horia Balan; Richard J Castriotta; Juan J Crespo; Yaron Dagan; Sherine El-Toukhy; José R Fernández; Garret A FitzGerald; Akio Fujimura; Yong-Jian Geng; Ramón G Hermida-Ayala; Antonio P Machado; Luiz Menna-Barreto; Artemio Mojón; Alfonso Otero; R Daniel Rudic; Eva Schernhammer; Carsten Skarke; Tomoko Y Steen; Martin E Young; Xiaoyun Zhao
Journal:  Chronobiol Int       Date:  2020-12-20       Impact factor: 3.749

6.  Variation in Blood Pressure Classification Using 7 Blood Pressure Estimation Protocols Among Adults in Taiwan.

Authors:  Hung-Ju Lin; Heng-Yu Pan; Wen-Jone Chen; Tzung-Dau Wang
Journal:  JAMA Netw Open       Date:  2020-11-02

7.  Assessment of psychiatric comorbidities and serotonergic or noradrenergic medication use on blood pressure using 24-hour ambulatory blood pressure monitoring.

Authors:  Shehzad K Niazi; Sobia H Memon; Elizabeth R Lesser; Emily Brennan; Nabeel Aslam
Journal:  J Clin Hypertens (Greenwich)       Date:  2021-06-29       Impact factor: 3.738

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.