Literature DB >> 8063300

Event-synchronous cancellation of the heart interference in biomedical signals.

P Strobach1, K Abraham-Fuchs, W Härer.   

Abstract

A two-pass adaptive filtering algorithm is proposed for cancellation of recurrent interferences such as the heart interference in biomedical signals. In the first pass, an average waveform in one period of the interference is estimated by event-synchronous (QRS-synchronous) averaging of the corrupted signal. In a second pass, an adaptive Schur recursive least squares (RLS) lattice filter is used to cancel the interference by using the event synchronously repeated estimated average waveform of the interference as an artificial reference signal. One key feature of this approach is that the ECG is only used for QRS synchronization and not directly as a reference signal for adaptive filtering. Thus the proposed algorithm can be applied to interference problems where ECG and true interference are almost synchronous but show considerably different waveforms. This is usually the case with the heart interference in biomedical signals. Both off-line and real-time implementations of the event synchronous interference canceller are described. The method is applied to the cancellation of the heart interference in magnetoencephalogram (MEG) signals and to the effective isolation of ventricular extrasystoles (VES) in magnetocardiogram (MCG) signals. Experimental results are shown. The new method typically attenuates the amplitudes of R-wave and T-wave interference components by an amplitude factor of 30 without influencing the MEG events of interest.

Entities:  

Mesh:

Year:  1994        PMID: 8063300     DOI: 10.1109/10.284962

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  7 in total

1.  Differential brain activity states during the perception and nonperception of illusory motion as revealed by magnetoencephalography.

Authors:  David A Crowe; Arthur C Leuthold; Apostolos P Georgopoulos
Journal:  Proc Natl Acad Sci U S A       Date:  2010-12-13       Impact factor: 11.205

2.  Real-time ocular artifact suppression using recurrent neural network for electro-encephalogram based brain-computer interface.

Authors:  A Erfanian; B Mahmoudi
Journal:  Med Biol Eng Comput       Date:  2005-03       Impact factor: 2.602

3.  Neural mechanisms of movement speed and tau as revealed by magnetoencephalography.

Authors:  Heng-Ru May Tan; Arthur C Leuthold; David N Lee; Joshua K Lynch; Apostolos P Georgopoulos
Journal:  Exp Brain Res       Date:  2009-05-08       Impact factor: 1.972

4.  A magnetoencephalography study of choice bias.

Authors:  William M Hedgcock; David A Crowe; Arthur C Leuthold; Apostolos P Georgopoulos
Journal:  Exp Brain Res       Date:  2009-12-11       Impact factor: 1.972

5.  Magnetoenterography (MENG): noninvasive measurement of bioelectric activity in human small intestine.

Authors:  W O Richards; L A Bradshaw; D J Staton; C L Garrard; F Liu; S Buchanan; J P Wikswo
Journal:  Dig Dis Sci       Date:  1996-12       Impact factor: 3.199

6.  A Combined Independent Source Separation and Quality Index Optimization Method for Fetal ECG Extraction from Abdominal Maternal Leads.

Authors:  Lucia Billeci; Maurizio Varanini
Journal:  Sensors (Basel)       Date:  2017-05-16       Impact factor: 3.576

7.  A Novel Technique for Fetal ECG Extraction Using Single-Channel Abdominal Recording.

Authors:  Nannan Zhang; Jinyong Zhang; Hui Li; Omisore Olatunji Mumini; Oluwarotimi Williams Samuel; Kamen Ivanov; Lei Wang
Journal:  Sensors (Basel)       Date:  2017-02-24       Impact factor: 3.576

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.