Value of routine pressure monitoring system changes after 72 hours of continuous use.

M K O'Malley1, F S Rhame, F B Cerra, R C McComb.   

Abstract

OBJECTIVE: To assess the infection potential of not routinely changing invasive monitoring kits and associated plasticware.
DESIGN: A prospective, observational study of microbiological contamination of a cohort of pressure monitoring infusion systems.
SETTING: Adult intensive care units in a university tertiary care center. PATIENTS: Patients who had invasively monitored arterial, central venous, or pulmonary artery catheters in place for > or = 96 hrs without a change to the system were entered into the study.
INTERVENTIONS: Fluid samples were obtained from the proximal stopcock of the monitoring kits every 24 hrs, beginning with a sample at 72 hrs and continuing until either the plasticware or catheter was changed or discontinued. Fluid samples were placed in tryptic soy broth and spread on blood agar plates within 24 hrs.
MEASUREMENTS AND MAIN RESULTS: Of 451 intervals in which the system remained unviolated for > or = 96 hrs except for sampling, no positive cultures were found. Of the 333 monitoring kits/lines in the study, four cultures became positive within 48 hrs of a violation of the system (flush bag change). Positive cultures were obtained from two different patients, one patient having positive fluid cultures from arterial, central venous, and pulmonary arterial kits. This bacterial growth would not have been eliminated with routine system changes as it occurred within a 48-hr timeframe.
CONCLUSIONS: Invasive hemodynamic pressure monitoring systems including tubing and plasticware need not be changed routinely as these changes may cause a higher incidence of contamination due to increased violations of the systems.

Entities:  

Mesh:

Year:  1994        PMID: 8062565     DOI: 10.1097/00003246-199409000-00012

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  3 in total

1.  Catheter-Related Bloodstream Infection.

Authors: 
Journal:  Curr Infect Dis Rep       Date:  1999-08       Impact factor: 3.725

Review 2.  Optimal timing for intravascular administration set replacement.

Authors:  Amanda J Ullman; Marie L Cooke; Donna Gillies; Nicole M Marsh; Azlina Daud; Matthew R McGrail; Elizabeth O'Riordan; Claire M Rickard
Journal:  Cochrane Database Syst Rev       Date:  2013-09-15

3.  Intravascular device administration sets: replacement after standard versus prolonged use in hospitalised patients-a study protocol for a randomised controlled trial (The RSVP Trial).

Authors:  Claire M Rickard; Nicole M Marsh; Joan Webster; Nicole C Gavin; Matthew R McGrail; Emily Larsen; Amanda Corley; Debbie Long; John R Gowardman; Marghie Murgo; John F Fraser; Raymond J Chan; Marianne C Wallis; Jeanine Young; David McMillan; Li Zhang; Md Abu Choudhury; Nicholas Graves; E Geoffrey Playford
Journal:  BMJ Open       Date:  2015-02-03       Impact factor: 2.692

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.