Literature DB >> 8060065

Factors affecting the rupture of silicone-gel breast implants.

W Peters1, E Keystone, D Smith.   

Abstract

Between January 1990 and April 1993, over 500 patients with silicone-gel breast implants were clinically assessed regarding their implant status. Of these, 57 patients requested implant removal. Reasons for removal were capsular contracture (39 patients), possible implant rupture, suggested by ultrasound testing or mammography (7 patients), "silicone phobia" (7 patients), and asymmetry (4 patients). Of the 102 implants that were removed, 60% were intact, 33% were ruptured, and 7% were leaking. There was a positive correlation between duration of implantation time and the number of ruptured and leaking implants. Of the 45 implants that had been in place for 5 years or less, 93% were intact. Of the 29 implants that had been in place for 6 to 10 years, only 31% were intact (59% were ruptured and 10% were leaking). Similar results were obtained in 20 implants after 11 to 15 years (30% were intact, 55% were ruptured, and 15% were leaking). Of 8 implants that were in place for 16 to 26 years, 50% were intact and 50% were ruptured. In this study, the integrity of breast implants was not related to the degree of capsular contracture.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8060065     DOI: 10.1097/00000637-199405000-00001

Source DB:  PubMed          Journal:  Ann Plast Surg        ISSN: 0148-7043            Impact factor:   1.539


  6 in total

1.  Breast prothesis leakage and malignant changes of the breast.

Authors:  Taha Al-Lawati; Rajyashree Kutty
Journal:  Oman Med J       Date:  2009-04

2.  Polyurethane-coated breast implants revisited: a 30-year follow-up.

Authors:  Nikki Castel; Taylor Soon-Sutton; Peter Deptula; Anna Flaherty; Fereydoun Don Parsa
Journal:  Arch Plast Surg       Date:  2015-03-16

3.  Silicone breast implants and depression, fibromyalgia and chronic fatigue syndrome in a rheumatology clinic population.

Authors:  Thomas Khoo; Susanna Proudman; Vidya Limaye
Journal:  Clin Rheumatol       Date:  2019-01-31       Impact factor: 2.980

Review 4.  The immunopathology of siliconosis. History, clinical presentation, and relation to silicosis and the chemistry of silicon and silicone.

Authors:  D R Shanklin; D L Smalley
Journal:  Immunol Res       Date:  1998       Impact factor: 2.829

5.  A retrospective analysis of ruptured breast implants.

Authors:  Woo Yeol Baek; Dae Hyun Lew; Dong Won Lee
Journal:  Arch Plast Surg       Date:  2014-11-03

6.  Subjective Cognitive Functioning in Silicone Breast Implant Patients: A Cohort Study.

Authors:  Maartje J L Colaris; Jan Willem Cohen Tervaert; Rudolf W H M Ponds; Johan Wilmink; Rene R W J van der Hulst
Journal:  Plast Reconstr Surg Glob Open       Date:  2021-02-17
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.