Literature DB >> 8059648

A mechanically detachable coil for the treatment of aneurysms and occlusion of blood vessels.

M P Marks1, H Chee, R P Liddell, G K Steinberg, N Panahian, B Lane.   

Abstract

PURPOSE: To evaluate mechanically detachable coil designs capable of controlled and instantaneous release within an aneurysm or vascular space.
METHODS: Three mechanically detachable coil designs, clamped ball, looped ribbon, and interlocking cylinder, were evaluated using in vitro and in vivo testing to study reliability of coil release, retractability, and coil behavior in a microcatheters. In vitro tests were performed using a glass side-wall aneurysm model and conventional microcatheters. In vivo experiments in rabbits included aneurysm models (side-wall and bifurcation) and arterial occlusions (carotid and renal).
RESULTS: All three designs deployed coils easily and were able to retract coils after partial deployment. Motion was seen in previously released coils and in the catheter when using the clamped ball and looped ribbon designs. The interlocking cylinder design did not cause similar motion. When compared with the other two designs, the interlocking cylinder had significantly greater separation forces between coil pusher and coil while in the catheter. Frictional forces within the catheter were lower for the interlocking cylinder mechanically detachable coil design than for a commercially available conventional coil and coil pusher system. During in vivo testing, the mechanically detachable coil design operated smoothly in the catheter, providing good release and retraction in aneurysms and straight vessels.
CONCLUSION: The interlocking cylinder mechanically detachable coil design is superior to the other two tested designs. The mechanically detachable coil was reliably delivered and detached in in vivo testing for the treatment of aneurysms and for the occlusion of blood vessels.

Entities:  

Mesh:

Year:  1994        PMID: 8059648      PMCID: PMC8332187     

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  8 in total

1.  Spiral versus J-shaped coils for neurovascular embolisation-an in-vitro study.

Authors:  K Sugiu; K Tokunaga; S Mandai; J B Martin; B Jean; D A Rüfenacht
Journal:  Neuroradiology       Date:  2003-06-11       Impact factor: 2.804

2.  A report of the clinical use of the detach-18 mechanical detachable platinum coil in 41 patients.

Authors:  K J Murph; E Houdart; K T Szopinski; O Levrier; L Guimaraens; D Kühne; L Solymosi; N J Bartholdy; K Sugiu; D A Rüfenacht
Journal:  AJNR Am J Neuroradiol       Date:  2001-02       Impact factor: 3.825

3.  The Underlying Mechanisms of Endovascular Exclusion of Intracranial Aneurysms by Coils. How Important is Electrothrombosis?

Authors:  H Henkes; S Brew; E Miloslavski; S Fischer; I Tavrovski; D Kühne
Journal:  Interv Neuroradiol       Date:  2004-10-22       Impact factor: 1.610

4.  In vitro and in vivo Studies of the Extent of Electrothrombotic Deposition of Blood Elements on the Surface of Electrolytically Detachable Coils.

Authors:  H Henkes; S Brew; S Felber; E Miloslavski; G Mogilevski; I Tavrovski; D Kühne
Journal:  Interv Neuroradiol       Date:  2005-01-05       Impact factor: 1.610

5.  The role of the endoscope in the transsphenoidal management of cystic lesions of the sellar region.

Authors:  Luigi M Cavallo; Daniel Prevedello; Felice Esposito; Edward R Laws; Joshua R Dusick; Andrea Messina; John A Jane; Daniel F Kelly; Paolo Cappabianca
Journal:  Neurosurg Rev       Date:  2007-10-06       Impact factor: 3.042

6.  Poly(2-hydroxyethyl methacrylate) emboli with increased haemostatic effect for correction of haemorrhage of complex origin in endovascular surgery of children.

Authors:  Daniel Horák; Ilya E Galibin; Arnold A Adamyan; Alexander V Sitnikov; Vasilii N Dan; Mariya I Titova; Vladimir V Shafranov; Yurii F Isakov; Klara Z Gumargalieva; Tatyana I Vinokurova
Journal:  J Mater Sci Mater Med       Date:  2007-08-21       Impact factor: 3.896

7.  Internal iliac artery embolization during an endovascular aneurysm repair with detachable interlock microcoils.

Authors:  Woo Chul Kim; Yong Sun Jeon; Kee Chun Hong; Jang Yong Kim; Soon Gu Cho; Jae Young Park
Journal:  Korean J Radiol       Date:  2014-09-12       Impact factor: 3.500

8.  Predictor's analysis of anterior circulation cerebral infarction after the endovascular treatment of anterior communicating artery aneurysms.

Authors:  Liqian Sun; Xiaobin Jing; Changmeng Cui; Jianzhong Cui
Journal:  J Res Med Sci       Date:  2014-04       Impact factor: 1.852

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.