Literature DB >> 8057807

Determination of proton magnetization transfer rate constants in heterogeneous biological systems.

D Brooks1, K Kuwata, T Schleich.   

Abstract

Two procedures are currently in use for the determination of proton magnetization transfer rate constants between macromolecular tissue components and water. The first method assumes that there are only two spin baths (macromolecular plus solvent) and that during off-resonance irradiation complete saturation of the "immobile" proton spin bath occurs (S. H. Koenig, R. D. Brown, III, R. Ugolini, Magn. Reson. Med. 29, 311 (1993)). This approach neglects the possibility of incomplete saturation and polydispersity, and yields an apparent magnetization transfer rate constant, Kapp. The second approach utilizes a formalism which can account for polydispersity and incomplete saturation of the immobile spin bath (K. Kuwata, D. Brooks, H. Yang, T. Schleich, J. Magn. Reson., in press). In this work magnetization transfer rate constants derived by the use of both methods for two systems, ocular lens tissue and cross-linked bovine serum albumin (BSA) were compared. For both samples Kapp was dependent on B2 off-resonance irradiation frequency and power when the first method was used. The second method provided values of the magnetization transfer rate constant that were similar to the values obtained by the first method, as the limit of complete saturation was approached.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8057807     DOI: 10.1002/mrm.1910310315

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  3 in total

1.  Dynamics of paramagnetic agents by off-resonance rotating frame technique in the presence of magnetization transfer effect.

Authors:  Huiming Zhang; Yang Xie
Journal:  J Magn Reson       Date:  2006-11-22       Impact factor: 2.229

2.  Quantification of magnetization transfer rate and native T1 relaxation time of the brain: correlation with magnetization transfer ratio measurements in patients with multiple sclerosis.

Authors:  Spyros Karampekios; Nickolas Papanikolaou; Eufrosini Papadaki; Thomas Maris; Kai Uffman; Martha Spilioti; Andreas Plaitakis; Nicholas Gourtsoyiannis
Journal:  Neuroradiology       Date:  2005-02-17       Impact factor: 2.804

3.  Magnetization transfer characteristics in atherosclerotic plaque components assessed by adapted binomial preparation pulses.

Authors:  M Pachot-Clouard; F Vaufrey; L Darrasse; J F Toussainti
Journal:  MAGMA       Date:  1998-11       Impact factor: 2.310

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.