Literature DB >> 805358

Build-up region of megavoltage photon radiation sources.

D E Velkley, D J Manson, J A Purdy, G D Oliver.   

Abstract

Measurements of surface dose and build-up have been measured for photon radiation sources with maximum energy from 1.2 to 25 MeV. A variable volume ionization chamber was used and the results extrapolated to what would be obtained with a zero volume chamber. The results are found to depend systematically on the plate separation of a parallel plate ionization chamber and an empirical method was derived for correcting measurements made with a fixed volume chamber. The relationship of dose build-up curves with skin reactions in radiation therapy patients is discussed.

Entities:  

Mesh:

Substances:

Year:  1975        PMID: 805358     DOI: 10.1118/1.594158

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  11 in total

1.  Comparison of surface dose delivered by 7 MV-unflattened and 6 MV-flattened photon beams.

Authors:  Ashokkumar Sigamani; Arunai Nambiraj
Journal:  Rep Pract Oncol Radiother       Date:  2017-04-25

2.  Absorption ratio of treatment couch and effect on surface and build-up region doses.

Authors:  Taylan Tuğrul
Journal:  Rep Pract Oncol Radiother       Date:  2017-11-20

3.  Analysis of small field percent depth dose and profiles: Comparison of measurements with various detectors and effects of detector orientation with different jaw settings.

Authors:  Henry Finlay Godson; M Ravikumar; S Sathiyan; K M Ganesh; Y Retna Ponmalar; C Varatharaj
Journal:  J Med Phys       Date:  2016 Jan-Mar

4.  Surface dose measurements with commonly used detectors: a consistent thickness correction method.

Authors:  Tatsiana A Reynolds; Patrick Higgins
Journal:  J Appl Clin Med Phys       Date:  2015-09-08       Impact factor: 2.102

5.  An investigation of the depth dose in the build-up region, and surface dose for a 6-MV therapeutic photon beam: Monte Carlo simulation and measurements.

Authors:  Lukkana Apipunyasopon; Somyot Srisatit; Nakorn Phaisangittisakul
Journal:  J Radiat Res       Date:  2012-10-26       Impact factor: 2.724

6.  Surface dose measurements and comparison of unflattened and flattened photon beams.

Authors:  Ashokkumar Sigamani; Arunai Nambiraj; Girigesh Yadav; Ananda Giribabu; Karthikeyan Srinivasan; Venkadamanickam Gurusamy; Kothanda Raman; Kaviarasu Karunakaran; Rajesh Thiyagarajan
Journal:  J Med Phys       Date:  2016 Apr-Jun

7.  Surface and buildup dose characteristics for 6, 10, and 18 MV photons from an Elekta Precise linear accelerator.

Authors:  Eric E Klein; Jacqueline Esthappan; Zuofeng Li
Journal:  J Appl Clin Med Phys       Date:  2003       Impact factor: 2.102

8.  Comparing dose in the build-up region between compensator- and MLC-based IMRT.

Authors:  Khosrow Javedan; Geoffrey G Zhang; Sarah Hoffe; Vladimir Feygelman; Kenneth Forster
Journal:  J Appl Clin Med Phys       Date:  2012-09-06       Impact factor: 2.102

9.  Beam perturbation characteristics of a 2D transmission silicon diode array, Magic Plate.

Authors:  Ziyad A Alrowaili; Michael L F Lerch; Marco Petasecca; Martin G Carolan; Peter E Metcalfe; Anatoly B Rosenfeld
Journal:  J Appl Clin Med Phys       Date:  2016-03-08       Impact factor: 2.102

10.  Surface dose variations in 6 and 10 MV flattened and flattening filter-free (FFF) photon beams.

Authors:  Jason Cashmore
Journal:  J Appl Clin Med Phys       Date:  2016-09-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.