Accuracy of subcutaneous fat measurement: comparison of skinfold calipers, ultrasound, and computed tomography.

C Orphanidou1, L McCargar, C L Birmingham, J Mathieson, E Goldner.   

Abstract

OBJECTIVE: The purpose of this study was to compare skinfold caliper and ultrasound measurement of subcutaneous body fat at three abdominal sites with computed tomography, which is considered to be the gold standard.
DESIGN: This was a cross-sectional study in which computed-tomography, ultrasound, and skinfold caliper measurements were made at three distinct abdominal sites. All body composition and anthropometric measurements were performed on each subject on one occasion.
SUBJECTS: Twenty-two subjects were recruited (13 men and 9 women). Mean ages (+/- standard deviation) were 43 +/- 4 years for the women and 51 +/- 18 years for the men. All subjects had been previously scheduled for an abdominal or pelvic computed-tomography scan at the Department of Radiology, St Paul's Hospital, Vancouver, British Columbia, Canada, and participated in the study on a volunteer basis. MAIN OUTCOME MEASURES: A better agreement was found between the skinfold calipers and computed-tomography methods than between the ultrasound and computed-tomography method for the measurement of subcutaneous body fat. This was observed when the data were analyzed for both correlational agreement and for graphical interpretation. STATISTICAL ANALYSES PERFORMED: The relationships among skinfold, ultrasound, and computed-tomography measurements were analyzed by determining Pearson correlation coefficients. A graphical method described by Bland and Altman was also used to assess agreement among the three methods.
RESULTS: Significant correlation coefficients were observed between skinfold calipers and computed tomography at all three abdominal sites (site 1, r = .60, P = .003; site 2, r = .70, P = .0001; site 3, r = .73, P = .0001). Ultrasound and computed-tomography methods only showed a significant correlation at site 3 (r = .54; P = .009). The graphical method revealed that the variation in the ultrasound measurements was much greater than that of the skinfold measurements when compared to computed-tomography values. APPLICATIONS/
CONCLUSIONS: The results of this study indicated that relative agreement in the measurement of subcutaneous body fat between skinfold and computed-tomography measurements was superior to that exhibited between ultrasound and computed-tomography measurements. This finding enhances the potential use of skinfold calipers in the clinical setting, particularly in view of the fact that measurement of subcutaneous body fat at different body sites is becoming increasingly important for the characterization of risk of certain disease states.

Entities:  

Mesh:

Year:  1994        PMID: 8046177     DOI: 10.1016/0002-8223(94)92363-9

Source DB:  PubMed          Journal:  J Am Diet Assoc        ISSN: 0002-8223


  19 in total

1.  Influence of the subcutaneous fat layer, as measured by ultrasound, skinfold calipers and BMI, on the EMG amplitude.

Authors:  C Nordander; J Willner; G-A Hansson; B Larsson; J Unge; L Granquist; S Skerfving
Journal:  Eur J Appl Physiol       Date:  2003-04-24       Impact factor: 3.078

2.  Reliability of Measuring Subcutaneous Fat Tissue Thickness Using Ultrasound in Non-Athletic Young Adults.

Authors:  Adela Chirita-Emandi; Andreea Dobrescu; Maria Papa; Maria Puiu
Journal:  Maedica (Buchar)       Date:  2015-09

3.  Quantifying the effect of adipose tissue in muscle oximetry by near infrared spectroscopy.

Authors:  Nassim Nasseri; Stefan Kleiser; Daniel Ostojic; Tanja Karen; Martin Wolf
Journal:  Biomed Opt Express       Date:  2016-10-17       Impact factor: 3.732

4.  Body composition in children based on anthropometric data. A presentation of normal values.

Authors:  W J Gerver; R de Bruin
Journal:  Eur J Pediatr       Date:  1996-10       Impact factor: 3.183

5.  Subcutaneous thigh fat assessment: a comparison of skinfold calipers and ultrasound imaging.

Authors:  Noelle M Selkow; Brian G Pietrosimone; Susan A Saliba
Journal:  J Athl Train       Date:  2011 Jan-Feb       Impact factor: 2.860

6.  Randomized trial of measures of body fat versus body weight in the treatment of anorexia nervosa.

Authors:  C L Birmingham; J L Muller; E M Goldner
Journal:  Eat Weight Disord       Date:  1998-06       Impact factor: 4.652

7.  Fat and fat-free mass in Nepalese children: an assessment of nutritional status.

Authors:  Arijit Ghosh; Shalini Choudhary; Sutanu Dutta Chowdhury; Tusharkanti Ghosh
Journal:  Eur J Pediatr       Date:  2009-07-14       Impact factor: 3.183

8.  Skinfold thickness for rivastigmine patch application in Alzheimer's disease.

Authors:  Ping-Song Chou; Kai-Ming Jhang; Ling-Chun Huang; Wen-Fu Wang; Yuan-Han Yang
Journal:  Psychopharmacology (Berl)       Date:  2019-01-15       Impact factor: 4.530

9.  Dietary Patterns Exhibit Sex-Specific Associations with Adiposity and Metabolic Risk in a Cross-Sectional Study in Urban Mexican Adolescents.

Authors:  Wei Perng; Carmen Fernandez; Karen E Peterson; ZhenZhen Zhang; Alejandra Cantoral; Brisa N Sanchez; Maritsa Solano-González; Martha Maria Téllez-Rojo; Ana Baylin
Journal:  J Nutr       Date:  2017-08-30       Impact factor: 4.798

10.  Ethnic differences in body fat distribution among Asian pre-pubertal children: a cross-sectional multicenter study.

Authors:  Ailing Liu; Nuala M Byrne; Masaharu Kagawa; Guansheng Ma; Kallaya Kijboonchoo; Lara Nasreddine; Bee Koon Poh; Mohammad Noor Ismail; Andrew P Hills
Journal:  BMC Public Health       Date:  2011-06-26       Impact factor: 3.295

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.