Literature DB >> 8040941

A compliant tubular device to study the influences of wall strain and fluid shear stress on cells of the vascular wall.

A Benbrahim1, G J L'Italien, B B Milinazzo, D F Warnock, S Dhara, J P Gertler, R W Orkin, W M Abbott.   

Abstract

PURPOSE: Cellular constituents of the blood vessel wall are continuously subjected, in vivo, to both mechanical and hemodynamic forces, which elicit structural and biologic responses. We have developed a compliant tubular system, the vascular simulating device (VSD), that reproduces these forces, while supporting the attachment and the experimental manipulation of endothelial and smooth muscle cells.
METHODS: The VSD consists of a compliant silicone rubber tube coupled to a pump system, which permits the simultaneous application of known levels of pressure and flow, to vascular wall cells cultured on the inner surface of the tube. Seeded cells can be monitored visually under phase contrast or fluorescent optics, as well as harvested and analyzed for biologic responses.
RESULTS: The elastic modulus and compliance of the silicone rubber tube are similar to those of canine and human arteries. Endothelial and smooth muscle cells cultured on the lumenal surface of the tubes remain attached and viable after subjecting them to physiologic pulsatile flow and cyclic strain.
CONCLUSION: The VSD makes it possible to approximate, in vitro, those forces encountered by vascular wall cells, in vivo and therefore may make it possible to determine whether specific combinations of mechanical and hemodynamic forces are causally associated with specific vascular diseases.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8040941     DOI: 10.1016/0741-5214(94)90005-1

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  3 in total

1.  Elastic membrane that undergoes mechanical deformation enhances osteoblast cellular attachment and proliferation.

Authors:  G K Toworfe; R J Composto; M H Lee; P Ducheyne
Journal:  Int J Biomater       Date:  2010-06-27

2.  An in vitro test bench reproducing coronary blood flow signals.

Authors:  Kamil Jerzy Chodzyński; Karim Zouaoui Boudjeltia; Jacques Lalmand; Adel Aminian; Luc Vanhamme; Daniel Ribeiro de Sousa; Simone Gremmo; Laurent Bricteux; Christine Renotte; Guy Courbebaisse; Grégory Coussement
Journal:  Biomed Eng Online       Date:  2015-08-07       Impact factor: 2.819

3.  A Novel Bioreactor System for the Assessment of Endothelialization on Deformable Surfaces.

Authors:  Björn J Bachmann; Laura Bernardi; Christian Loosli; Julian Marschewski; Michela Perrini; Martin Ehrbar; Paolo Ermanni; Dimos Poulikakos; Aldo Ferrari; Edoardo Mazza
Journal:  Sci Rep       Date:  2016-12-12       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.