Literature DB >> 8040038

A simple device to position large/flaccid breasts during tangential breast irradiation.

G C Bentel1, L B Marks.   

Abstract

PURPOSE: It is technically difficult to irradiate large pendulous or flaccid breasts with tangential photon fields because they often lie very high or lateral on the chestwall. We, therefore, designed a device to reposition the breast on the chestwall to facilitate treatment. METHODS AND MATERIALS: A device to aid in repositioning the breast on the chestwall has been designed. The device consists of a reinforced polyvinylchloride tube formed into a ring that is placed around the breast. A strap around the patient's chest holds the ring in place. The breast tissue is manually moved to the desired position on the chestwall, whereafter the strap is tightened to maintain the position. Treatment setup marks are placed on the skin peripheral to the breast and on the immobilization mold.
RESULTS: Twelve patients with large/flaccid breasts were successfully treated with this device. The technical and physician staff find the reproducibility and acute treatment reactions to be acceptable. Anatomically, the use of this device reduces the volume of lung tissue otherwise included in the tangential fields in patients where the breast lies far lateral. In patients where the breast lies too far cephalad on the chestwall for tangential fields to clear the arm, repositioning of the breast with this device makes tangential fields possible.
CONCLUSION: This repositioning appliance aids in the radiation treatment of patients with large or flaccid breasts and, in some instances, renders otherwise nontreatable patients treatable with radiation therapy.

Entities:  

Mesh:

Year:  1994        PMID: 8040038     DOI: 10.1016/0360-3016(94)90580-0

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  2 in total

1.  A new three-dimensional conformal radiotherapy (3DCRT) technique for large breast and/or high body mass index patients: evaluation of a novel fields assessment aimed to reduce extra-target-tissue irradiation.

Authors:  Stimato Gerardina; Ippolito Edy; Silipigni Sonia; Di Venanzio Cristina; Rinaldi Carla Germana; Gaudino Diego; Fiore Michele; Trodella Lucio; D'Angelillo Rolando Maria; Ramella Sara
Journal:  Br J Radiol       Date:  2016-06-29       Impact factor: 3.039

2.  The role of a prone setup in breast radiation therapy.

Authors:  Nelly Huppert; Gabor Jozsef; Keith Dewyngaert; Silvia Chiara Formenti
Journal:  Front Oncol       Date:  2011-10-11       Impact factor: 6.244

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.