Literature DB >> 8037084

Implantable cardioverter-defibrillator therapy in 300 patients with coronary artery disease presenting exclusively with ventricular fibrillation.

T J Lessmeier1, M H Lehmann, R T Steinman, B S Fromm, M Akhtar, H Calkins, J P DiMarco, A E Epstein, N A Estes, R N Fogoros.   

Abstract

To determine outcomes of implantable cardioverter-defibrillator (ICD) therapy in a uniform population of survivors of sudden cardiac death, we used epicardial defibrillation lead systems to study 300 patients with coronary artery disease (CAD) presenting exclusively with ventricular fibrillation (VF) unassociated with acute myocardial infarction. Operative (30-day) mortality, 2.7% overall, was lower (0.6%) in patients with ejection fractions (EF) > or = 0.30. Over a median follow-up of 1.9 years, cumulative actuarial shock incidence was similar in patients who underwent concomitant coronary artery bypass graft (CABG) surgery (38%) and in those who did not. The 2-year cumulative actuarial incidences of any or appropriate shocks were 65% and 38%, respectively. Sudden death survival at 2 years was 92.5% and 99.3% for patients with EFs < or = 0.30 and > 0.30, respectively. The total mortality rate was similar in shocked and in unshocked patients. Multivariate analysis identified EF and female gender as significant predictors of any and appropriate shock occurrence (all p values < or = 0.05) and EF as a significant predictor of sudden, cardiac, and total mortality (all p values < 0.03). We conclude that in CAD patients presenting exclusively with VF unassociated with acute myocardial infarction and treated with thoracotomy-requiring ICD therapy: (1) operative (30-day) mortality is minimal for patients with an EF > or = 0.30; (2) device use is high and sudden death rates low regardless of concomitant CABG; (3) low EF is a significant predictor of cumulative shock occurrence and mortality (sudden, cardiac, and total); (4) female gender may be a predictor of shock occurrence; and (5) similar mortalities and low sudden-death rates in shocked and nonshocked ICD patients imply that ICD therapy improves survival in shocked patients to a level observed in comparable patients in whom ventricular tachyarrhythmia does not recur.

Entities:  

Mesh:

Year:  1994        PMID: 8037084     DOI: 10.1016/0002-8703(94)90470-7

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  7 in total

1.  Sudden Cardiac Death.

Authors: 
Journal:  Curr Treat Options Cardiovasc Med       Date:  1999-08

2.  [Strategies to avoid complications and to solve technical problems during the implantation of CRT and CRT-D systems].

Authors:  M Stockburger
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2006

3.  Quality of life predicts one-year survival in patients with implantable cardioverter defibrillators.

Authors:  Chi-Wen Kao; Erika Friedmann; Sue A Thomas
Journal:  Qual Life Res       Date:  2010-02-03       Impact factor: 4.147

Review 4.  The management of ventricular arrhythmias in older patients after CAST.

Authors:  W S Aronow
Journal:  Drugs Aging       Date:  1995-02       Impact factor: 3.923

5.  Implantable defibrillators for secondary prevention of sudden cardiac death in cardiac surgery patients with perioperative ventricular arrhythmias.

Authors:  Maged F Nageh; John J Kim; Lie-Hong Chen; Janis F Yao
Journal:  J Am Heart Assoc       Date:  2014-08-21       Impact factor: 5.501

6.  Sex Difference in Clinical Outcome of Patients With Implantable Cardioverter-defibrillator.

Authors:  Neshat Nazari; Sima Sayah; Nasrin Safavi; Mostafa Hekmat; Zahra Emkanjoo
Journal:  Res Cardiovasc Med       Date:  2013-02-24

7.  The effect of revascularization on mortality and risk of ventricular arrhythmia in patients with ischemic cardiomyopathy.

Authors:  Ahmad Alkharaza; Mousa Al-Harbi; Ihab El-Sokkari; Steve Doucette; Ciorsti MacIntyre; Christopher Gray; Amir Abdelwahab; John L Sapp; Martin Gardner; Ratika Parkash
Journal:  BMC Cardiovasc Disord       Date:  2020-10-21       Impact factor: 2.298

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.