Literature DB >> 8031804

Breath pentane is a marker of acute cardiac allograft rejection.

P A Sobotka1, D K Gupta, D M Lansky, M R Costanzo, E J Zarling.   

Abstract

Breath pentane, a product of lipid peroxidation that serves as a noninvasive marker of tissue inflammation and injury, was measured as a potential marker of acute cardiac allograft rejection. We prospectively studied 37 consecutive outpatients with stable cardiac allograft function. Breath pentane levels were measured with gas chromatography, and the results were compared the findings from routine surveillance endomyocardial biopsy. Data analysis was performed with the receiver operating characteristic curve and negative and positive predictive values. Statistical methods include analysis of variance and two-sample t-tests. Histopathologic findings consistent with rejection were present on endomyocardial biopsy in 52% of the subjects. Pentane levels in healthy control subjects did not differ from those of patients undergoing transplantation without rejection. Average pentane excretion for subjects with mild rejection (4.2 +/- 2.8 nmol/L) or moderate rejection (5.4 +/- 2.6 nmol/L) exceeded that seen in subjects who did not have rejection (1.7 +/- 0.9 nmol/L) (p < 0.02). A pentane cutoff value of 2.43 nmol/L, chosen to give the highest negative predictive value, had a sensitivity of 0.80. We concluded that breath pentane excretion is a sensitive noninvasive screening test for the detection of cardiac allograft rejection.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8031804

Source DB:  PubMed          Journal:  J Heart Lung Transplant        ISSN: 1053-2498            Impact factor:   10.247


  5 in total

1.  Noninvasive detection of acute heart rejection: the quest for the perfect test.

Authors:  M Ballester; I Carrió
Journal:  J Nucl Cardiol       Date:  1997 May-Jun       Impact factor: 5.952

2.  Oxidative stress in the human heart is associated with changes in the antioxidative defense as shown after heart transplantation.

Authors:  I Schimke; M Schikora; R Meyer; H P Dübel; D Modersohn; F X Kleber; G Baumann
Journal:  Mol Cell Biochem       Date:  2000-01       Impact factor: 3.396

3.  Application of Cavity Enhanced Absorption Spectroscopy to the Detection of Nitric Oxide, Carbonyl Sulphide, and Ethane--Breath Biomarkers of Serious Diseases.

Authors:  Jacek Wojtas
Journal:  Sensors (Basel)       Date:  2015-06-17       Impact factor: 3.576

4.  Breath biomarkers of insulin resistance in pre-diabetic Hispanic adolescents with obesity.

Authors:  Mohammad S Khan; Suzanne Cuda; Genesio M Karere; Laura A Cox; Andrew C Bishop
Journal:  Sci Rep       Date:  2022-01-10       Impact factor: 4.379

Review 5.  Cardiovascular biomarkers in body fluids: progress and prospects in optical sensors.

Authors:  Reena V John; Tom Devasiya; Nidheesh V R; Sphurti Adigal; Jijo Lukose; V B Kartha; Santhosh Chidangil
Journal:  Biophys Rev       Date:  2022-08-18
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.