Literature DB >> 8031686

Measurements of interface pressure between body sites and the surfaces of four specialised air mattresses.

V Allen1, D W Ryan, A Murray.   

Abstract

Four specialised air mattresses had interface pressure measured under six body sites prone to pressure sores in 10 subjects, supine and sitting. The mattresses were the Clinirest (SSI) and FirstStep (KCI) continuous airflow mattress overlays, and Airwave (Pegasus) and Nimbus (Huntleigh) alternating pressure air mattresses. On the mattress overlays, average supine interface pressures were 2.33 kPa (scapula), 4.15 kPa (elbow), 1.94 kPa (sacrum) and 2.79 kPa (buttock), although they were higher at the occiput (7.97 kPa) and heel (11.7 kPa). The alternating pressure air mattresses had an average minimum interface pressure close to zero for three sites, rising to 4.28 kPa under the heel. Average maximum interface pressures were 8.61 kPa (occiput), 5.21 kPa (scapula), 4.90 (elbow), 4.85 kPa (sacrum), 4.61 kPa (buttock) and 13.2 kPa (heel). No accepted scientific method exists for comparing the two types of mattress. Our data suggest a clinical benefit at the occiput and heel (supine) in using an alternating pressure air mattress and a benefit in using a continuous airflow mattress overlay at other sites.

Mesh:

Year:  1994        PMID: 8031686

Source DB:  PubMed          Journal:  Br J Clin Pract        ISSN: 0007-0947


  5 in total

Review 1.  Backrest position in prevention of pressure ulcers and ventilator-associated pneumonia: conflicting recommendations.

Authors:  Ruth Srednicki Burk; Mary Jo Grap
Journal:  Heart Lung       Date:  2012-07-21       Impact factor: 2.210

2.  Prevention of pressure ulcer: interaction of body characteristics and different mattresses.

Authors:  Theodoros Moysidis; Wolfgang Niebel; Katharina Bartsch; Irene Maier; Nils Lehmann; Michael Nonnemacher; Knut Kroeger
Journal:  Int Wound J       Date:  2011-10-17       Impact factor: 3.315

3.  The Need for Head Protection Protocols for Craniectomy Patients during Rest, Transfers and Turning.

Authors:  Anand S Pandit; Prabhav Singhal; Sogha Khawari; Astri M V Luoma; Sara Ajina; Ahmed K Toma
Journal:  Front Surg       Date:  2022-05-20

Review 4.  Evaluation of antidecubitus mattresses.

Authors:  A Jonsson; M Lindén; M Lindgren; L-A Malmqvist; Y Bäcklund
Journal:  Med Biol Eng Comput       Date:  2005-09       Impact factor: 3.079

5.  Evaluation of external pressure to the sacral region in the lithotomy position using the noninvasive pressure distribution measurement system.

Authors:  Ju Mizuno; Toru Takahashi
Journal:  Ther Clin Risk Manag       Date:  2017-02-17       Impact factor: 2.423

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.