Literature DB >> 8026377

Management of a persistent pancreatic fistula secondary to a ruptured pseudocyst with endoscopic insertion of an expandable metal stent.

E Gane1, S Fata'ar, I Hamilton.   

Abstract

A case of pancreatic fistula successfully managed by the endoscopic insertion of an expanding-mesh metal stent into the pancreatic duct is reported. The patient had developed a fistula following rupture of a pancreatic pseudocyst, and attempted transpapillary drainage using plastic endoprostheses had failed due to prosthesis migration. Insertion of a Strecker metal stent was followed by rapid and sustained clinical improvement and cessation of fistula drainage.

Entities:  

Mesh:

Year:  1994        PMID: 8026377     DOI: 10.1055/s-2007-1008955

Source DB:  PubMed          Journal:  Endoscopy        ISSN: 0013-726X            Impact factor:   10.093


  2 in total

Review 1.  Outcome of stenting in biliary and pancreatic benign and malignant diseases: A comprehensive review.

Authors:  Benedetto Mangiavillano; Nico Pagano; Todd H Baron; Carmelo Luigiano
Journal:  World J Gastroenterol       Date:  2015-08-14       Impact factor: 5.742

2.  Endoscopic management of pancreatic fistulas secondary to intraabdominal operation.

Authors:  A Fischer; S Benz; P Baier; U T Hopt
Journal:  Surg Endosc       Date:  2004-03-19       Impact factor: 4.584

  2 in total